| − | + | This is [[Granity]] motor drive configuration & tuning software user guide main page. Please find individual articles below or browse [[:Category:Granity]]. | |
| − | + | ==Granity user interface controls and parameters== | |
| − | [[ | + | *[[Granity user guide/Connect|Connect tab]] |
| − | [[ | + | *[[Granity user guide/Goals|Goals tab]] |
| − | [[ | + | *[[Granity user guide/Machine|Machine tab]] |
| − | [[ | + | *[[Granity user guide/Tuning|Tuning tab]] |
| − | [[Category: | + | *[[Granity user guide/Fault limits|Fault limits tab]] |
| + | *[[Granity user guide/Testing|Testing tab]] | ||
| + | ==Other Granity usage related articles== | ||
| + | *[[Granity user guide/Uploading a firmware|Uploading a drive firmware]] | ||
| + | *[[Servo motor tuning guide]] | ||
| + | |||
| + | ==Hotkeys== | ||
| + | Granity 1.5.1 and later support global hotkeys | ||
| + | ;Alt+O | ||
| + | :Connect to drive | ||
| + | ;Alt+D | ||
| + | :Disconnect from drive | ||
| + | ;Esc | ||
| + | :Disable drive | ||
| + | ;Alt+A | ||
| + | :Apply settings | ||
| + | ;Alt+1 | ||
| + | :Set absolute setpoint 1 (TSP1) | ||
| + | ;Alt+2 | ||
| + | :Set absolute setpoint 2 (TSP2) | ||
| + | ;Alt+3 | ||
| + | :Increment setpoint 1 (TSP1) | ||
| + | ;Alt+4 | ||
| + | :Increment setpoint 2 (TSP2) | ||
| + | ;Alt+0 | ||
| + | :Set setpoint to zero | ||
| + | ;Alt+S | ||
| + | :Start scope capture | ||
| + | ;Alt+W | ||
| + | :[[Downloading offline scope capture in Granity|Download offline scope capture]] (Granity 1.12.0 or later) | ||
| + | ;Alt+R | ||
| + | :Clear faults | ||
| + | ;Ctrl+S | ||
| + | :Save settings to file | ||
| + | ;Ctrl+O | ||
| + | :Open settings file | ||
| + | ;Ctrl+Alt+Q | ||
| + | :Set drive in Quick stop mode (if supported) | ||
| + | ;Ctrl+Alt+R | ||
| + | :Reset drive Quick stop mode (if supported) | ||
| + | |||
| + | {{next|[[Granity user guide/Connect]]}} | ||
| + | [[Category:Granity user guide]] | ||
Latest revision as of 14:31, 16 October 2018
This is Granity motor drive configuration & tuning software user guide main page. Please find individual articles below or browse Category:Granity.
Granity user interface controls and parameters[edit | edit source]
[edit | edit source]
Hotkeys[edit | edit source]
Granity 1.5.1 and later support global hotkeys
- Alt+O
- Connect to drive
- Alt+D
- Disconnect from drive
- Esc
- Disable drive
- Alt+A
- Apply settings
- Alt+1
- Set absolute setpoint 1 (TSP1)
- Alt+2
- Set absolute setpoint 2 (TSP2)
- Alt+3
- Increment setpoint 1 (TSP1)
- Alt+4
- Increment setpoint 2 (TSP2)
- Alt+0
- Set setpoint to zero
- Alt+S
- Start scope capture
- Alt+W
- Download offline scope capture (Granity 1.12.0 or later)
- Alt+R
- Clear faults
- Ctrl+S
- Save settings to file
- Ctrl+O
- Open settings file
- Ctrl+Alt+Q
- Set drive in Quick stop mode (if supported)
- Ctrl+Alt+R
- Reset drive Quick stop mode (if supported)