Difference between revisions of "IONI device model comparison"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(→Comparison) |
|||
Line 10: | Line 10: | ||
*Torque mode effects: damping, friction and inertia (useful in simulator applications) | *Torque mode effects: damping, friction and inertia (useful in simulator applications) | ||
*[[SimuCUBE]] simulator motherboard support | *[[SimuCUBE]] simulator motherboard support | ||
+ | *Serial encoder support | ||
;The planned IONI Pro features are: | ;The planned IONI Pro features are: | ||
− | |||
*Support for EtherCAT field bus (through separate EtherCAT to [[SimpleMotion V2]] bridge device) | *Support for EtherCAT field bus (through separate EtherCAT to [[SimpleMotion V2]] bridge device) | ||
*True [[dual-loop feedback position control]] | *True [[dual-loop feedback position control]] | ||
− | + | ||
The planned features are implemented as user downlodable firmware. Firmware upgrades are free. | The planned features are implemented as user downlodable firmware. Firmware upgrades are free. |
Latest revision as of 09:36, 1 January 2020
The main difference between IONI and IONI Pro is that Pro model will get more advanced functions as downloadable upgrades.
- Available exclusive IONI Pro features
- SinCos 1 Vp-p encoder support
- Motor torque cogging & ripple compensation
- Notch filter for advanced vibration damping
- Power consumption limit (useful with switch mode power supplies)
- Homing function and soft travel limits that work in all control modes, not just position control mode
- Torque mode effects: damping, friction and inertia (useful in simulator applications)
- SimuCUBE simulator motherboard support
- Serial encoder support
- The planned IONI Pro features are
- Support for EtherCAT field bus (through separate EtherCAT to SimpleMotion V2 bridge device)
- True dual-loop feedback position control
The planned features are implemented as user downlodable firmware. Firmware upgrades are free.
Comparison[edit | edit source]
The table below summarizes the full list of realized differences. All base features are available in all models. For full list of features, see IONI specifications.
Feature | IONI | IONI Pro | IONI Pro HC |
---|---|---|---|
Max output current (AC/BLDC/Stepper) | 15 A | 18 A | 25 A |
Max output current (Brush DC) | 23.4 A | 30 A | 30 A |
Supply voltage range | 5-52 VDC | 5-52 VDC (Rev1)
5-55 VDC (Rev2) |
5-55 VDC (all revisions) |
Feedback device (i.e. encoder) resolution | 100-15000000 P/R with incremental encoders | 100-15000000 P/R with incremental encoders. For absolute serial encoder (BiSS, SSI), see details at Using serial data feedback device. | |
Max encoder count rate | 0-4 MHz | 0-18 MHz | |
Pulse and direction setpoint frequency | 0-4 MHz | 0-8 MHz | |
Quadrature setpoint frequency | 0-1 MHz | 0-2 MHz | |
Sin/Cos encoder support | No | Yes, selectable resolution interpolation factor 16X, 64X or 256X | |
SSI absolute encoder support | No | Yes | |
BiSS absolute encoder support | No | Yes | |
Motor torque cogging & ripple compensation (anticogging) | No | Yes | |
Notch & peaking torque filter (advanced machine resonance attenuation) | No | Yes | |
Motor homing function availability | Yes, in position control mode | Yes, in position, velocity and torque control modes | |
User definable HV DC bus power consumption limit | No | Yes, 1-1000 W at 1 W steps | |
SimuCUBE support | No | Yes | |
Torque mode effects (simulator applications) | No | Yes |
Note: specifications and planned updates are subject to change without notice.