Line 65: | Line 65: | ||
**Address an issue where overspeed fault (parameter [[FEV]]) has no effect and not causing fault | **Address an issue where overspeed fault (parameter [[FEV]]) has no effect and not causing fault | ||
*New features | *New features | ||
− | **Added support for analog SinCos encoder feedback device | + | **Added support for analog SinCos encoder feedback device in IONI Pro model |
**Added application specific features for torque control mode (rotation angle limit & torque scaling by analog input) | **Added application specific features for torque control mode (rotation angle limit & torque scaling by analog input) | ||
*Improvements | *Improvements | ||
Line 71: | Line 71: | ||
**Increased [[Phasing a.k.a. phase search]] algorithm motor swing to allow successful phasing in the case where motor motion is blocked in one direction | **Increased [[Phasing a.k.a. phase search]] algorithm motor swing to allow successful phasing in the case where motor motion is blocked in one direction | ||
**Motor inductance & resistance measurement function (introduced V1.1.0) adjusted to be less sensitive to motor motion during the test | **Motor inductance & resistance measurement function (introduced V1.1.0) adjusted to be less sensitive to motor motion during the test | ||
− | || The | + | || The SinCos support requires [[Granity]] V 1.7.0 |
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! | Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! |
Revision as of 22:07, 3 May 2015
This page lists the official firmware releases of the IONI Servo Drive and the change log.
Upgrading firmware
Read instructions from Granity user guide/Uploading a firmware.
Releases
- Glossary
- Firmware release version - a firmware file with .gdf name extension that contains the firmware firmware
- Version code - the version shown in Granity
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware release version | Date | Version code | Change log | Remarks | Importance |
---|---|---|---|---|---|
1.0.0 | 15.3.2015 | 1050 |
|
||
1.0.1 | 19.3.2015 | 1052 |
|
Medium | |
1.0.2 | 11.4.2015 | 1054 |
|
Important upgrade due to overcurrent protection fix and phasing current calcuation fix. | Very high |
1.0.3 | 12.4.2015 | 1056 |
|
Medium | |
1.0.4 download | 13.4.2015 | 1058 |
|
Medium | |
1.1.0 download | 15.4.2015 | 1060 |
|
The new feature requires Granity V 1.6.0 | Medium (High for DC motor users) |
1.2.0 download | 4.5.2015 | 1062 |
|
The SinCos support requires Granity V 1.7.0
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! |
Medium |
Known bugs & limitations
Bugs that are known in the latest FW revision:
- Setpoint smoothing does not have effect in velocity or torque modes (only position mode)