IONI LED indicators
- LED1 Motor control state indicator (green)
- LED2 Fault indicator (orange)
How to read indications[edit | edit source]
- LED1 and LED2 have programmed blinking sequences. Sequences consists series of short (S) and long (L) light pulses. For example LLS means the led will blink two long flashs and then one short flash. After sequence there will be a pause before the sequence repeats.
- LED1 and LED2 are independent and can show fault and motor state simultaneously. To easier reading sequence, cover one led with a thumb to be able to concentrate to one led.
- LED2 and shows the first fault occurred if multiple fault states are active simultaneously.
- LED1 and LED2 are flashing together if device is in a firmware upgrade mode (DFU).
List of all LED1 and LED2 sequences[edit | edit source]
To see animated images, view this Wiki page in a web browser with animations enabled. The animations show Argon front panel, but the blinking sequences of IONI are equivalent when LED1=LD4 and LED2=LD3.
Faults[edit | edit source]
Only LED2 is being controlled by these faults, except in DFU mode when both leds blink together.
Fault reason | LED sequence | LED sequence as text |
---|---|---|
Hardware | LLSS | |
Progral or memory | LSLL | |
Internal comm error (CRC) | LSL | |
Initialization | LSS | |
Over current | SLL | |
Over temperature | LSLS | |
Over voltage | SLS | |
Following error | LS | |
Under voltage | SL | |
Motion blocked or motor runaway | SSL | |
Setpoint range exceeded | LSSL | |
SimpleMotion communication error | LSSS | |
Other/unknown, possibly configuration error such as motor mode Motor typeMT not selected | SSSL |
Motor control states[edit | edit source]
Only LED1 is being controlled by these states.
IONICUBE LED indicators[edit | edit source]
IONICUBE has four LED indicators that will are dedicated to:
- LED1
- Power on (24V supplied)
- LED2
- GPO1_X (LED on when GPO1_X is high)
- LED3
- Fault stop state (LED on when any of drives has fault stop state on)
- LED4
- Regenerative resistor is being driven
LED1-4 on IONICUBE
Read next |
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.