Difference between revisions of "IONI specifications overview table"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
(ce update)
 
(19 intermediate revisions by 2 users not shown)
Line 59: Line 59:
 
|-
 
|-
 
| Power supply||
 
| Power supply||
*Externally supplied 5 – 52 VDC
+
*Externally supplied  
 +
**IONI, IONI Pro 5 – 52 VDC
 +
**IONI Pro HC 5 - 55 VDC
 
*Additionally an external 5 VDC logic supply required. ''Note: if drive is used with [[IONICUBE]] motherboards, then 24 VDC logic supply voltage is needed instead as IONICUBE has on-board 5V regulator.''
 
*Additionally an external 5 VDC logic supply required. ''Note: if drive is used with [[IONICUBE]] motherboards, then 24 VDC logic supply voltage is needed instead as IONICUBE has on-board 5V regulator.''
  
 
|-
 
|-
| Motor output current||
+
| Motor output current<sup>1</sup>||
* 0-15 A continuous & peak current with sufficient coolant air flow ([[Peak value of sine|peak of sine]])
+
* AC/BLDC/Stepping/Linear motors (current specified as [[Peak value of sine|peak of sine]]):
* Current level is automatically throttled by temperature rise
+
**IONI 0-15 A
 +
**IONI Pro 0-18 A
 +
**IONI Pro HC 0-25 A
 +
* Brush DC motors:
 +
**IONI 0-19.5 A
 +
**IONI Pro 0-23.4 A
 +
**IONI Pro HC 0-30 A
 
|-
 
|-
 
| Commissioning||
 
| Commissioning||
Line 71: Line 79:
 
* [[IONI & IONICUBE user guide|Online user guide]]
 
* [[IONI & IONICUBE user guide|Online user guide]]
 
|-
 
|-
| Compliance || CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005
+
| Compliance || CE (LVD & EMC): EN IEC 62368-1:2018, IEC 61000-6-1:2005 and IEC 61000-6-3:2006.
 +
SIL2: IEC 61800-5-2:2016-04
 +
 
 +
Notes:
 +
* In order to meet EMC standard requirements, a proper installation and wiring is necessary. Refer to user guide for proper installation.
 +
* Signed Declaration of Conformity will be provided on request.
 +
|-
 +
|Reliability
 +
|
 +
* MTBF: 2.99 million hours
 +
* Failure rate (all delivered units, actual statistic from 2015-2017): 0.36%
 
|}
 
|}
 +
<sup>1</sup>) Currents achievable continuously only with with sufficient coolant air flow. Without forced cooling, typically 30-45% of the maximum range can be driven continuously. Despite of this, maximum current is available for short periods of time even without cooling. Current is automatically throttled on temperature rise to protect the drive.

Latest revision as of 15:17, 11 February 2021

Function Description
Servo/stepping motor drive Closed loop control of various types of servo motors by sinusoidal field oriented control with dead-time distortion correction and high dynamic range torque control.
  • Synchronous AC & BLDC motors
    • Sinusoidal and trapezoidal commutated
    • SPM (Surface Permanent Magnet) and IPM (Internal Permanent Magnet) types
  • Brush DC motors
  • Linear motors
    • Iron core
    • Ironless (with external inductive filter)
  • Stepping motor, 2 phase (4,6 or 8 wires)
Control modes
  • Torque control
  • Velocity/speed control
  • Position control
Setpoint types

See setpoint signal / reference inputs list

Closed loop Cascaded control loops (PIV):
  • Torque / current control, update frequency 20.0 kHz
  • Velocity control, update frequency 2.5 kHz
  • Position control, update frequency 2.5 kHz
Feed-forwards Feed-forwards working in velocity & position control modes:
  • Acceleration (inertia canceling) feed-forward
  • Velocity (friction canceling) feed-forward
Homing Integrated homing function for position control mode:
  • Sensorless hard-stop homing
  • Home switch search
  • Index pulse search
  • Soft position limits (eliminate limit switches)
Feedback devices See feedback devices list
Safety
  • Safe torque off with 3-way redundancy
  • Charge pump enable input
  • Stopping motor on errors
    • Tracking error (velocity & position)
    • Over speed error
    • Limit switch
  • DC motor runaway prevention on feedback loss
  • Communication error detection
Protections
  • Over current
  • Short circuit (phase-to-phase)
  • I2t motor thermal protection
  • Over & under voltage
  • Over temperature
Power supply
  • Externally supplied
    • IONI, IONI Pro 5 – 52 VDC
    • IONI Pro HC 5 - 55 VDC
  • Additionally an external 5 VDC logic supply required. Note: if drive is used with IONICUBE motherboards, then 24 VDC logic supply voltage is needed instead as IONICUBE has on-board 5V regulator.
Motor output current1
  • AC/BLDC/Stepping/Linear motors (current specified as peak of sine):
    • IONI 0-15 A
    • IONI Pro 0-18 A
    • IONI Pro HC 0-25 A
  • Brush DC motors:
    • IONI 0-19.5 A
    • IONI Pro 0-23.4 A
    • IONI Pro HC 0-30 A
Commissioning
Compliance CE (LVD & EMC): EN IEC 62368-1:2018, IEC 61000-6-1:2005 and IEC 61000-6-3:2006.

SIL2: IEC 61800-5-2:2016-04

Notes:

  • In order to meet EMC standard requirements, a proper installation and wiring is necessary. Refer to user guide for proper installation.
  • Signed Declaration of Conformity will be provided on request.
Reliability
  • MTBF: 2.99 million hours
  • Failure rate (all delivered units, actual statistic from 2015-2017): 0.36%

1) Currents achievable continuously only with with sufficient coolant air flow. Without forced cooling, typically 30-45% of the maximum range can be driven continuously. Despite of this, maximum current is available for short periods of time even without cooling. Current is automatically throttled on temperature rise to protect the drive.