Difference between revisions of "IONI firmware releases"
From Granite Devices Knowledge Wiki
[quality revision] | [checked revision] |
(→Releases) |
(→Releases) |
||
Line 75: | Line 75: | ||
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! | Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! | ||
|| Medium | || Medium | ||
+ | |||
+ | |- | ||
+ | | 1.2.1 [[Media:IONIFWpackage1.2.1.gdf|download]] || 3.6.2015|| 1064 || | ||
+ | *Fixes | ||
+ | **Address an issue where GPI5 did not start homing | ||
+ | **Correct offset correction calculation in PWM and Analog setpoint modes (when [[CAO]] is non-zero and [[CED]] is enabled) | ||
+ | *Improvements | ||
+ | **Reduce sensitivity of gain parameters to suit better for very high resolution feedback devices: | ||
+ | ***[[KVP]] and [[KPP]] have sensitivty of 1/5 compared to to earlier firmware (to preserve old gain, multiply old gain values by 5 after upgrade) | ||
+ | ***[[VFF]] has sensitivty of 1/10 compared to to earlier firmware (to preserve old gain, multiply old gain value by 10 after upgrade) | ||
+ | **Increased maximum value range of gain parameters from 32767 to 300000 | ||
+ | || Note: adjust KVP, KPP and VFF values after upgrade! See change log for details. | ||
+ | || Low | ||
|} | |} | ||
Revision as of 13:46, 3 June 2015
This page lists the official firmware releases of the IONI Servo Drive and the change log.
Upgrading firmware
Read instructions from Granity user guide/Uploading a firmware.
Releases
- Glossary
- Firmware release version - a firmware file with .gdf name extension that contains the firmware firmware
- Version code - the version shown in Granity
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware release version | Date | Version code | Change log | Remarks | Importance |
---|---|---|---|---|---|
1.0.0 | 15.3.2015 | 1050 |
|
||
1.0.1 | 19.3.2015 | 1052 |
|
Medium | |
1.0.2 | 11.4.2015 | 1054 |
|
Important upgrade due to overcurrent protection fix and phasing current calcuation fix. | Very high |
1.0.3 | 12.4.2015 | 1056 |
|
Medium | |
1.0.4 download | 13.4.2015 | 1058 |
|
Medium | |
1.1.0 download | 15.4.2015 | 1060 |
|
The new feature requires Granity V 1.6.0 | Medium (High for DC motor users) |
1.2.0 download | 4.5.2015 | 1062 |
|
The SinCos support requires Granity V 1.7.0
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! |
Medium |
1.2.1 download | 3.6.2015 | 1064 |
|
Note: adjust KVP, KPP and VFF values after upgrade! See change log for details. | Low |
Known bugs & limitations
Bugs that are known in the latest FW revision:
- Setpoint smoothing does not have effect in velocity or torque modes (only position mode)