Difference between revisions of "IONI specifications overview table"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
Line 63: Line 63:
  
 
|-
 
|-
| Motor output current||
+
| Motor output current<sup>1</sup>||
* 0-15 A (IONI), 0-18 A (IONI Pro), 0-23 A (IONI Pro HC) continuous & peak current with sufficient coolant air flow ([[Peak value of sine|peak of sine]])
+
* AC/BLDC/Stepping/Linear motors: 0-15 A (IONI), 0-18 A (IONI Pro), 0-23 A (IONI Pro HC) continuous & peak current ([[Peak value of sine|peak of sine]])
 +
* Brush DC motors: 0-19.5 A (IONI), 0-23.4 A (IONI Pro), 0-30 A (IONI Pro HC) continuous & peak current
 
* Current level is automatically throttled by temperature rise
 
* Current level is automatically throttled by temperature rise
 
|-
 
|-
Line 73: Line 74:
 
| Compliance || CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005
 
| Compliance || CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005
 
|}
 
|}
 +
<sup>1</sup>) Currents achievable continuously only with with sufficient coolant air flow. Without forced cooling, typically 30-45% of the maximum range can be driven continuously. Despite of this, maximum current is available for short periods of time even without cooling. Current is automatically throttled on temperature rise to protect the drive.

Revision as of 23:15, 4 November 2015

Function Description
Servo/stepping motor drive Closed loop control of various types of servo motors by sinusoidal field oriented control with dead-time distortion correction and high dynamic range torque control.
  • Synchronous AC & BLDC motors
    • Sinusoidal and trapezoidal commutated
    • SPM (Surface Permanent Magnet) and IPM (Internal Permanent Magnet) types
  • Brush DC motors
  • Linear motors
    • Iron core
    • Ironless (with external inductive filter)
  • Stepping motor, 2 phase (4,6 or 8 wires)
Control modes
  • Torque control
  • Velocity/speed control
  • Position control
Setpoint types

See setpoint signal / reference inputs list

Closed loop Cascaded control loops (PIV):
  • Torque / current control, update frequency 20.0 kHz
  • Velocity control, update frequency 2.5 kHz
  • Position control, update frequency 2.5 kHz
Feed-forwards Feed-forwards working in velocity & position control modes:
  • Acceleration (inertia canceling) feed-forward
  • Velocity (friction canceling) feed-forward
Homing Integrated homing function for position control mode:
  • Sensorless hard-stop homing
  • Home switch search
  • Index pulse search
  • Soft position limits (eliminate limit switches)
Feedback devices See feedback devices list
Safety
  • Safe torque off with 3-way redundancy
  • Charge pump enable input
  • Stopping motor on errors
    • Tracking error (velocity & position)
    • Over speed error
    • Limit switch
  • DC motor runaway prevention on feedback loss
  • Communication error detection
Protections
  • Over current
  • Short circuit (phase-to-phase)
  • I2t motor thermal protection
  • Over & under voltage
  • Over temperature
Power supply
  • Externally supplied 5 – 52 VDC (IONI, IONI Pro), 5 - 55 (IONI Pro HC)
  • Additionally an external 5 VDC logic supply required. Note: if drive is used with IONICUBE motherboards, then 24 VDC logic supply voltage is needed instead as IONICUBE has on-board 5V regulator.
Motor output current1
  • AC/BLDC/Stepping/Linear motors: 0-15 A (IONI), 0-18 A (IONI Pro), 0-23 A (IONI Pro HC) continuous & peak current (peak of sine)
  • Brush DC motors: 0-19.5 A (IONI), 0-23.4 A (IONI Pro), 0-30 A (IONI Pro HC) continuous & peak current
  • Current level is automatically throttled by temperature rise
Commissioning
Compliance CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005

1) Currents achievable continuously only with with sufficient coolant air flow. Without forced cooling, typically 30-45% of the maximum range can be driven continuously. Despite of this, maximum current is available for short periods of time even without cooling. Current is automatically throttled on temperature rise to protect the drive.