|
|
Line 144: |
Line 144: |
| **IONI Pro HC model maximum output current in AC/BLDC/Stepper modes increased to 25A (was 23A) | | **IONI Pro HC model maximum output current in AC/BLDC/Stepper modes increased to 25A (was 23A) |
| **DC motor mode no longer requires parallel connection of drive output phases if current is at most 50% of drive's maximum output current capability (sensitivity of overcurrent fault with Fault ID 440219 is greatly reduced). | | **DC motor mode no longer requires parallel connection of drive output phases if current is at most 50% of drive's maximum output current capability (sensitivity of overcurrent fault with Fault ID 440219 is greatly reduced). |
− | **Reduced torque control noise (audible). Noise reduction is active when {{param|TBW}} is set 680 Hz or less.
| |
| *Fixes | | *Fixes |
| **Changed limit switch polarity: earlier limit switches needed to be normally open (NO), while drive specifications say that they are normally closed type (NC). Now limit switchers are NC (switch conducting -> motion allowed, switch open -> motion stops). | | **Changed limit switch polarity: earlier limit switches needed to be normally open (NO), while drive specifications say that they are normally closed type (NC). Now limit switchers are NC (switch conducting -> motion allowed, switch open -> motion stops). |
Revision as of 12:31, 31 December 2015
This page lists the official firmware releases of the IONI Servo Drive and the change log.
Upgrading firmware
Read instructions from Granity user guide/Uploading a firmware.
Releases
- Glossary
- Firmware release version - a firmware file with .gdf name extension that contains the firmware firmware
- Version code - the version shown in Granity
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware release version |
Date |
Version code |
Change log |
Remarks |
Importance
|
1.0.0 |
15.3.2015 |
1050 |
|
|
|
1.0.1 |
19.3.2015 |
1052 |
- Address an issue where device may trigger watchdog reset under heavy use
|
|
Medium
|
1.0.2 |
11.4.2015 |
1054 |
- Fixes
- Fix Phasing a.k.a. phase search current calculation when Thermal time constantMTC is set below 400 seconds. Avoids too high current flow to motor.
- Fix overcurrent condition observer (OC fault was not always triggered when it should).
- Fix incorrect setpoint scaling when using Setpoint smoothingCIS Setpoint smoothing function (before 1.0.2 CIS caused setpoint to incorrectly scale by 1:2)
- Fix functionality of GPI5 input (homing start)
- Fix override parameter function (more info: Reading and writing an arbitrary parameter with Granity)
- Improvements
- Reduce Phasing a.k.a. phase search current to avoid motor heating at initialization
- Improve open loop stepping motor performance
- GPO3 (fault output) will be push-pull instead of open drain when electrical interface is set Standard (for IONICUBE 1X compatibility)
- IONI Indiegogo campaign drives have 18 Amp maximum current limit instead of 15 A (serial number based)
|
Important upgrade due to overcurrent protection fix and phasing current calcuation fix. |
Very high
|
1.0.3 |
12.4.2015 |
1056 |
- Fixes
- Fix clear faults command by Enable signal in IONICUBE electrical interface mode
- Fix PWM setpoint operation after setpoint source has been changed from pulse/direction to PWM
- Improvements
- Stepping motor has automatic current reduction/boost depending on whether motor is standing still or rotating (switch between configured continuous and peak current).
|
|
Medium
|
1.0.4 |
13.4.2015 |
1058 |
- Fixes
- Address an issue where Achieved torque readout & graph was showing only zero
- Improvements
|
|
Medium
|
1.1.0 download |
15.4.2015 |
1060 |
- Fixes
- Fix incorrect (too high) current scale for Brush DC motors
- New features
- Improvements
- Extend the maximum range of resistance and inductance parameters from 32 ohm & mH to above 100 ohm & mH
|
The new feature requires Granity V 1.6.0 |
Medium (High for DC motor users)
|
1.2.0 download |
4.5.2015 |
1062 |
- Fixes
- Address an issue where overspeed fault (parameter Over speed faultFEV) has no effect and not causing fault
- New features
- Improvements
- Increase feed-forward gain sensitivities: velocity FF Velocity feed-forward gainVFF sensitivity is 30 times higher, and acceleration FF Acceleration feed-forward gainAFF is 300 times higher than before
- Increased Phasing a.k.a. phase search algorithm motor swing to allow successful phasing in the case where motor motion is blocked in one direction
- Motor inductance & resistance measurement function (introduced V1.1.0) adjusted to be less sensitive to motor motion during the test
|
The SinCos support requires Granity V 1.7.0
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade!
|
Medium
|
1.2.1 download |
3.6.2015 |
1064 |
- Fixes
- Address an issue where GPI5 did not start homing
- Fix signal offset compensation calculation in PWM and Analog setpoint modes (applies when Setpoint offset nullingCAO is non-zero and Enable direction inputCED is enabled)
- Improvements
- Reduce sensitivity of gain parameters to suit better for very high resolution feedback devices:
- Velocity P gainKVP and Position P gainKPP have sensitivty of 1/5 compared to to earlier firmware (to preserve old gain, multiply old gain values by 5 after upgrade)
- Velocity feed-forward gainVFF has sensitivty of 1/10 compared to to earlier firmware (to preserve old gain, multiply old gain value by 10 after upgrade)
- Increased maximum value range of gain parameters from 32767 to 300000
|
Note: adjust KVP, KPP and VFF values after upgrade! See change log for details.
|
Low
|
1.2.2 download |
23.6.2015 |
1068 |
- Fixes
- Stepper motor mode no longer reduces motor current in steady velocity motion (reduction occurred when a long motion setpoint was commanded via serial command)
- Target reached status made to work properly
- Improvements
- Homing current limit Motor current limit during homingHMT parameter is now effective also in stepper mode
|
|
Low
|
1.2.3 download |
15.7.2015 |
1070 |
- Fixes
- Fix PWM+Dir setpoint mode (was giving only setpoint zero in FW 1.2.1 and 1.2.2)
- Improvements
- Drive current limit increased to 18 A in IONI Pro model
|
|
Low
|
1.3.0 download |
2.11.2015 |
1080 |
- New features
- Fixes
- Avoid overcurrent problem after Phasing a.k.a. phase search with high current motors
- Allow outputting the 18 A current on IONI Pro (was still limited to 15 A in previous version)
- Servo ready status updated correctly now
- Addressed an issue where GPO5 output did not change state
- Reduced sensitivity to overcurrent fault when using DC motor
- Improvements
- Drive current limit increased on DC motor mode on all IONI models:
- 19.5 A on IONI
- 23.4 A on IONI Pro
- 30.0 A on IONI Pro HC
- Added possibility to disable hard stop detection in homing (set zero to Hard stop detection thresholdHMH)
- Position mode error recovery motion mode now uses velocity limit Acceleration limitCAL, not Homing acceleration limitHMA
- Hard-stop homing parameterizing made more logical - now Offset move after homingHMF can be left zero without issues
|
Requires Granity V 1.9.0
|
Low
|
1.3.1 download |
25.11.2015 |
1082 |
- Improvements
- Reduced torque control noise (audible). Noise reduction is active when Torque bandwidth limitTBW is set 680 Hz or less.
|
|
Low
|
1.4.0 download |
31.12.2015 |
1084 |
- Improvements
- Use 32 bit floating point arithmetics in torque controller instead of integer arithmetics (at least theoretical precision improvement)
- IONI Pro HC model maximum output current in AC/BLDC/Stepper modes increased to 25A (was 23A)
- DC motor mode no longer requires parallel connection of drive output phases if current is at most 50% of drive's maximum output current capability (sensitivity of overcurrent fault with Fault ID 440219 is greatly reduced).
- Fixes
- Changed limit switch polarity: earlier limit switches needed to be normally open (NO), while drive specifications say that they are normally closed type (NC). Now limit switchers are NC (switch conducting -> motion allowed, switch open -> motion stops).
- Fix an issue where AC/BLDC motor initialization could become incorrectly phased when Hall sensors are enabled
- Address an issue where torque was 5% lower than setpoint with TBW parameter value of 4700 Hz
|
- Test the upgrade with caution due to significant internal changes
- If system uses limit switches, they need to be wired differently after upgrade, or disable them with LFS parameter
|
Medium
|
Known bugs & limitations
Bugs that are known in the latest FW revision:
- Setpoint smoothing does not have effect in velocity or torque modes (only position mode)
- Install firmware button in Granity does not always have effect with IONICUBE (4 axis). Workaround: insert jumper in position 3 of JP10 and restart 24V power to force devices in firmware upgrade mode.