Line 63: | Line 63: | ||
|- | |- | ||
− | | Motor output current|| | + | | Motor output current<sup>1</sup>|| |
− | * 0-15 A (IONI), 0-18 A (IONI Pro), 0-23 A (IONI Pro HC) continuous & peak current | + | * AC/BLDC/Stepping/Linear motors: 0-15 A (IONI), 0-18 A (IONI Pro), 0-23 A (IONI Pro HC) continuous & peak current ([[Peak value of sine|peak of sine]]) |
+ | * Brush DC motors: 0-19.5 A (IONI), 0-23.4 A (IONI Pro), 0-30 A (IONI Pro HC) continuous & peak current | ||
* Current level is automatically throttled by temperature rise | * Current level is automatically throttled by temperature rise | ||
|- | |- | ||
Line 73: | Line 74: | ||
| Compliance || CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005 | | Compliance || CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005 | ||
|} | |} | ||
+ | <sup>1</sup>) Currents achievable continuously only with with sufficient coolant air flow. Without forced cooling, typically 30-45% of the maximum range can be driven continuously. Despite of this, maximum current is available for short periods of time even without cooling. Current is automatically throttled on temperature rise to protect the drive. |
Revision as of 23:15, 4 November 2015
Function | Description |
---|---|
Servo/stepping motor drive | Closed loop control of various types of servo motors by sinusoidal field oriented control with dead-time distortion correction and high dynamic range torque control.
|
Control modes |
|
Setpoint types |
See setpoint signal / reference inputs list
|
Closed loop | Cascaded control loops (PIV):
|
Feed-forwards | Feed-forwards working in velocity & position control modes:
|
Homing | Integrated homing function for position control mode:
|
Feedback devices | See feedback devices list |
Safety |
|
Protections |
|
Power supply |
|
Motor output current1 |
|
Commissioning |
|
Compliance | CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005 |
1) Currents achievable continuously only with with sufficient coolant air flow. Without forced cooling, typically 30-45% of the maximum range can be driven continuously. Despite of this, maximum current is available for short periods of time even without cooling. Current is automatically throttled on temperature rise to protect the drive.