This page lists the official firmware releases of the IONI Servo Drive and the change log.
Upgrading firmware
Read instructions from Granity user guide/Uploading a firmware.
Releases
- Glossary
- Firmware release version - a firmware file with .gdf name extension that contains the firmware firmware
- Version code - the version shown in Granity
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware release version |
Date |
Version code |
Change log |
Remarks |
Importance
|
1.0.0 |
15.3.2015 |
1050 |
|
|
|
1.0.1 |
19.3.2015 |
1052 |
- Address an issue where device may trigger watchdog reset under heavy use
|
|
Medium
|
1.0.2 |
11.4.2015 |
1054 |
- Fixes
- Fix Phasing a.k.a. phase search current calculation when Thermal time constantMTC is set below 400 seconds. Avoids too high current flow to motor.
- Fix overcurrent condition observer (OC fault was not always triggered when it should).
- Fix incorrect setpoint scaling when using Setpoint smoothingCIS Setpoint smoothing function (before 1.0.2 CIS caused setpoint to incorrectly scale by 1:2)
- Fix functionality of GPI5 input (homing start)
- Fix override parameter function (more info: Reading and writing an arbitrary parameter with Granity)
- Improvements
- Reduce Phasing a.k.a. phase search current to avoid motor heating at initialization
- Improve open loop stepping motor performance
- GPO3 (fault output) will be push-pull instead of open drain when electrical interface is set Standard (for IONICUBE 1X compatibility)
- IONI Indiegogo campaign drives have 18 Amp maximum current limit instead of 15 A (serial number based)
|
Important upgrade due to overcurrent protection fix and phasing current calcuation fix. |
Very high
|
1.0.3 |
12.4.2015 |
1056 |
- Fixes
- Fix clear faults command by Enable signal in IONICUBE electrical interface mode
- Fix PWM setpoint operation after setpoint source has been changed from pulse/direction to PWM
- Improvements
- Stepping motor has automatic current reduction/boost depending on whether motor is standing still or rotating (switch between configured continuous and peak current).
|
|
Medium
|
1.0.4 |
13.4.2015 |
1058 |
- Fixes
- Address an issue where Achieved torque readout & graph was showing only zero
- Improvements
|
|
Medium
|
1.1.0 download |
15.4.2015 |
1060 |
- Fixes
- Fix incorrect (too high) current scale for Brush DC motors
- New features
- Improvements
- Extend the maximum range of resistance and inductance parameters from 32 ohm & mH to above 100 ohm & mH
|
The new feature requires Granity V 1.6.0 |
Medium (High for DC motor users)
|
1.2.0 download |
4.5.2015 |
1062 |
- Fixes
- Address an issue where overspeed fault (parameter Over speed faultFEV) has no effect and not causing fault
- New features
- Improvements
- Increase feed-forward gain sensitivities: velocity FF Velocity feed-forward gainVFF sensitivity is 30 times higher, and acceleration FF Acceleration feed-forward gainAFF is 300 times higher than before
- Increased Phasing a.k.a. phase search algorithm motor swing to allow successful phasing in the case where motor motion is blocked in one direction
- Motor inductance & resistance measurement function (introduced V1.1.0) adjusted to be less sensitive to motor motion during the test
|
The SinCos support requires Granity V 1.7.0
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade!
|
Medium
|
1.2.1 download |
3.6.2015 |
1064 |
- Fixes
- Address an issue where GPI5 did not start homing
- Fix signal offset compensation calculation in PWM and Analog setpoint modes (applies when Setpoint offset nullingCAO is non-zero and Enable direction inputCED is enabled)
- Improvements
- Reduce sensitivity of gain parameters to suit better for very high resolution feedback devices:
- Velocity P gainKVP and Position P gainKPP have sensitivty of 1/5 compared to to earlier firmware (to preserve old gain, multiply old gain values by 5 after upgrade)
- Velocity feed-forward gainVFF has sensitivty of 1/10 compared to to earlier firmware (to preserve old gain, multiply old gain value by 10 after upgrade)
- Increased maximum value range of gain parameters from 32767 to 300000
|
Note: adjust KVP, KPP and VFF values after upgrade! See change log for details.
|
Low
|
1.2.2 download |
23.6.2015 |
1068 |
- Fixes
- Stepper motor mode no longer reduces motor current in steady velocity motion (reduction occurred when a long motion setpoint was commanded via serial command)
- Target reached status made to work properly
- Improvements
- Homing current limit Motor current limit during homingHMT parameter is now effective also in stepper mode
|
|
Low
|
1.2.3 download |
15.7.2015 |
1070 |
- Fixes
- Fix PWM+Dir setpoint mode (was giving only setpoint zero in FW 1.2.1 and 1.2.2)
- Improvements
- Drive current limit increased to 18 A in IONI Pro model
|
|
Low
|
1.3.0 download |
2.11.2015 |
1080 |
- New features
- Fixes
- Avoid overcurrent problem after Phasing a.k.a. phase search with high current motors
- Allow outputting the 18 A current on IONI Pro (was still limited to 15 A in previous version)
- Servo ready status updated correctly now
- Addressed an issue where GPO5 output did not change state
- Reduced sensitivity to overcurrent fault when using DC motor
- Improvements
- Drive current limit increased on DC motor mode on all IONI models:
- 19.5 A on IONI
- 23.4 A on IONI Pro
- 30.0 A on IONI Pro HC
- Added possibility to disable hard stop detection in homing (set zero to Hard stop detection thresholdHMH)
- Position mode error recovery motion mode now uses velocity limit Acceleration limitCAL, not Homing acceleration limitHMA
- Hard-stop homing parameterizing made more logical - now Offset move after homingHMF can be left zero without issues
|
Requires Granity V 1.9.0
|
Low
|
1.3.1 download |
25.11.2015 |
1082 |
- Improvements
- Reduced torque control noise (audible). Noise reduction is active when Torque bandwidth limitTBW is set 680 Hz or less.
|
|
Low
|
1.4.0 download |
31.12.2015 |
1084 |
- Improvements
- IONI Pro HC model maximum output current in AC/BLDC/Stepper modes increased to 25A (was 23A)
- Re-implemented torque controller using 32 bit floating point arithmetics instead of integer arithmetics (at least theoretical precision improvement)
- DC motor mode no longer requires parallel connection of drive output phases if current is at most 50% of drive's maximum output current capability (sensitivity of overcurrent fault with Fault ID 440219 is greatly reduced).
- Fixes
- Changed limit switch polarity: earlier limit switches needed to be normally open (NO), while drive specifications say that they are normally closed type (NC). Now limit switchers are NC (switch conducting -> motion allowed, switch open -> motion stops).
- Fix an issue where AC/BLDC motor initialization could become incorrectly phased when Hall sensors are enabled
- Address an issue where torque was 5% lower than setpoint with TBW parameter value of 4700 Hz
|
- Test the upgrade with caution due to significant internal changes
- If system uses limit switches, they need to be wired differently after upgrade, or disable them with LFS parameter
|
Medium
|
1.5.0-BETA1 download |
6.4.2016 |
1090 |
- New features (IONI Pro/Pro HC only):
- Notch/peaking filter for torque setpoint
- Torque mode effects added: damping, friction and inertia
- Homing function that works in all control modes
- Power consumption limit parameter added (allow setting maximum power driven to motor)
- SimuCUBE support added in Electrical interfaceCEI
- New features (all models):
- Support for fast setpoint command added in SimpleMotion V2 protocol
- Improvements
- Smoother multi-axis operation in buffered motion stream mode (SimpleMotion V2)
- Added function to run self-test of the internal RAM of controller at power-on
- Fixes
- Address an issue where fault location 6601 was rarely induced after power-on
|
- Test the upgrade with caution due to significant internal changes
- Use Granity V1.10 or later to access the new features
|
Medium
|
Known bugs & limitations
Bugs that are known in the latest FW revision:
- Setpoint smoothing does not have effect in velocity or torque modes (only position mode)
- Install firmware button in Granity does not always have effect with IONICUBE (4 axis). Workaround: insert jumper in position 3 of JP10 and restart 24V power to force devices in firmware upgrade mode.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.