| [[Setpoint]] types||
 
| [[Setpoint]] types||
 
See [[IONI specifications#Setpoint_signal_.2F_reference_inputs|setpoint signal / reference inputs]] list
 
See [[IONI specifications#Setpoint_signal_.2F_reference_inputs|setpoint signal / reference inputs]] list
*Direct set-point tracking via [[pulse and direction]], {{param|PWM}}, [[Analog setpoint|Analog]], [[Quadrature]], [[SimpleMotion V2]]
+
*Direct set-point tracking via [[pulse and direction]], [[PWM]], [[Analog setpoint|Analog]], [[Quadrature]], [[SimpleMotion V2]]
 
*[[Pulse burst positioning]]
 
*[[Pulse burst positioning]]
 
*Buffered synchronous motion commands via [[SimpleMotion V2]]
 
*Buffered synchronous motion commands via [[SimpleMotion V2]]

Revision as of 19:58, 28 August 2015

Function Description
Servo/stepping motor drive Closed loop control of various types of servo motors by sinusoidal field oriented control with dead-time distortion correction and high dynamic range torque control.
  • Synchronous AC & BLDC motors
    • Sinusoidal and trapezoidal commutated
    • SPM (Surface Permanent Magnet) and IPM (Internal Permanent Magnet) types
  • Brush DC motors
  • Linear motors
    • Iron core
    • Ironless (with external inductive filter)
  • Stepping motor, 2 phase (4,6 or 8 wires)
Control modes
  • Torque control
  • Velocity/speed control
  • Position control
Setpoint types

See setpoint signal / reference inputs list

Closed loop Cascaded control loops (PIV):
  • Torque / current control, update frequency 20.0 kHz
  • Velocity control, update frequency 2.5 kHz
  • Position control, update frequency 2.5 kHz
Feed-forwards Feed-forwards working in velocity & position control modes:
  • Acceleration (inertia canceling) feed-forward
  • Velocity (friction canceling) feed-forward
Homing Integrated homing function for position control mode:
  • Sensorless hard-stop homing
  • Home switch search
  • Index pulse search
  • Soft position limits (eliminate limit switches)
Feedback devices See feedback devices list
Safety
  • Safe torque off with 3-way redundancy
  • Charge pump enable input
  • Stopping motor on errors
    • Tracking error (velocity & position)
    • Over speed error
    • Limit switch
  • DC motor runaway prevention on feedback loss
  • Communication error detection
Protections
  • Over current
  • Short circuit (phase-to-phase)
  • I2t motor thermal protection
  • Over & under voltage
  • Over temperature
Power supply
  • Externally supplied 5 – 52 VDC
  • Additionally an external 5 VDC logic supply required. Note: if drive is used with IONICUBE motherboards, then 24 VDC logic supply voltage is needed instead as IONICUBE has on-board 5V regulator.
Motor output current
  • 0-18 A (IONI Pro) 0-15 A (IONI) continuous & peak current with sufficient coolant air flow (peak of sine)
  • Current level is automatically throttled by temperature rise
Commissioning
Compliance CE (LVD & EMC): EN 61800-5-1:2007 and IEC 61000-6-1:2005