Difference between revisions of "IONI firmware releases"
[checked revision] | [checked revision] |
(→Releases) (Tag: VisualEditor) |
(Tag: VisualEditor) |
||
Line 277: | Line 277: | ||
*''Install firmware'' button in Granity does not always have effect with IONICUBE (4 axis). Workaround: insert jumper in position 3 of JP10 and restart 24V power to force devices in firmware upgrade mode. This minor issue affects only first production run IONI drives shipped around April 2015 to June 2015. | *''Install firmware'' button in Granity does not always have effect with IONICUBE (4 axis). Workaround: insert jumper in position 3 of JP10 and restart 24V power to force devices in firmware upgrade mode. This minor issue affects only first production run IONI drives shipped around April 2015 to June 2015. | ||
*Overcurrent fault with [[Fault location]] 402001 may cause false alarms on some setups. Improvements in future firwmare are planned. If problem occurs, as workaround set {{param|FOC}} to Maximum. | *Overcurrent fault with [[Fault location]] 402001 may cause false alarms on some setups. Improvements in future firwmare are planned. If problem occurs, as workaround set {{param|FOC}} to Maximum. | ||
+ | |||
+ | == Credits, copyrights and third party software in IONI firmware == | ||
+ | Several fantastic pieces of open-source software have helped get IONI firmware to where it is today. For fur list of credits, see [[Third-party licenses]]. | ||
{{machine|As firmware changes may affect the behavior of the drive/motor sometimes in unexpected ways, pay attention to machine safety and be prepared for unexpected motion. '''It is a good safety practice to disconnect motor shaft before upgrading and during testing.''' If problems encountered, please report us. We will fix firmware issues as first priority task. }} | {{machine|As firmware changes may affect the behavior of the drive/motor sometimes in unexpected ways, pay attention to machine safety and be prepared for unexpected motion. '''It is a good safety practice to disconnect motor shaft before upgrading and during testing.''' If problems encountered, please report us. We will fix firmware issues as first priority task. }} |
Revision as of 11:26, 4 March 2017
This page lists the official firmware releases of the IONI Servo Drive and the change log.
Contents
[hide]Upgrading firmware
Read instructions from Granity user guide/Uploading a firmware.
Releases
- Glossary
- Firmware release version - a firmware file with .gdf name extension that contains the firmware firmware
- Version code - the version shown in Granity
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware release version | Date | Version code | Change log | Remarks | Importance |
---|---|---|---|---|---|
1.0.0 | 15.3.2015 | 1050 |
|
||
1.0.1 | 19.3.2015 | 1052 |
|
Medium | |
1.0.2 | 11.4.2015 | 1054 |
|
Important upgrade due to overcurrent protection fix and phasing current calcuation fix. | Very high |
1.0.3 | 12.4.2015 | 1056 |
|
Medium | |
1.0.4 | 13.4.2015 | 1058 |
|
Medium | |
1.1.0 download | 15.4.2015 | 1060 |
|
The new feature requires Granity V 1.6.0 | Medium (High for DC motor users) |
1.2.0 download | 4.5.2015 | 1062 |
|
The SinCos support requires Granity V 1.7.0
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! |
Medium |
1.2.1 download | 3.6.2015 | 1064 |
|
Note: adjust KVP, KPP and VFF values after upgrade! See change log for details. | Low |
1.2.2 download | 23.6.2015 | 1068 |
|
Low | |
1.2.3 download | 15.7.2015 | 1070 |
|
Low | |
1.3.0 download | 2.11.2015 | 1080 |
|
Requires Granity V 1.9.0 | Low |
1.3.1 download | 25.11.2015 | 1082 |
|
Low | |
1.4.0 download | 31.12.2015 | 1084 |
|
|
Medium |
1.5.0 download | 8.5.2016 | 1092 |
|
|
Low |
1.5.1 download | 6.6.2016 | 1094 |
|
Medium | |
1.5.2 | 4.8.2016 | 1096 |
|
In open loop stepper mode, update KVI and KPP parameters according to page Using stepping motor with IONI | Medium |
1.5.3 download | 11.8.2016 | 1098 |
|
See also notes of 1.5.2. | Medium |
1.5.4 download | 8.9.2016 | 1100 |
|
It may be necessary to decrease FUV and/or increase FOV parameter values to make drive initialize as the new changes requires 2% safety headroom for these values versus actual supply voltage.
I.e. for 48.0V supply voltage, the FUV value should be less than 48*0.98=47V and FOV should be greater than 48/0.98=49V. In practice, make allowed voltage range at least 0.5V wider to allow supply voltage variation, like FUV=46.5V and FOV=49.5V or greater. For more information, see Configuring drive voltage limits FUV and FOV |
Medium |
1.5.5 download | 19.12.2016 | 1102 |
|
Medium | |
1.5.6 download | 16.1.2017 | 1104 |
|
Maximum FOC setting is still safe value for drive. | Low |
1.5.8 download | 14.2.2017 | 1108 |
|
This, or later version is required for drives manufactured after 1.2017 due to minor hardware change. Installing older FW version on such device will cause update error and requires re-update. | Low |
Beta releases
Firmware release version | Date | Version code | Change log | Remarks | Importance |
---|---|---|---|---|---|
1.6.0-beta1 download | 23.1.2017 | 1190 |
|
|
Low |
Known bugs & limitations
Bugs that are known in the latest FW revision:
- Setpoint smoothing does not have effect in velocity or torque modes (only position mode)
- Install firmware button in Granity does not always have effect with IONICUBE (4 axis). Workaround: insert jumper in position 3 of JP10 and restart 24V power to force devices in firmware upgrade mode. This minor issue affects only first production run IONI drives shipped around April 2015 to June 2015.
- Overcurrent fault with Fault location 402001 may cause false alarms on some setups. Improvements in future firwmare are planned. If problem occurs, as workaround set Over current toleranceFOC to Maximum.
Credits, copyrights and third party software in IONI firmware
Several fantastic pieces of open-source software have helped get IONI firmware to where it is today. For fur list of credits, see Third-party licenses.
![]() | As firmware changes may affect the behavior of the drive/motor sometimes in unexpected ways, pay attention to machine safety and be prepared for unexpected motion. It is a good safety practice to disconnect motor shaft before upgrading and during testing. If problems encountered, please report us. We will fix firmware issues as first priority task. |