Argon's J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake.
+
{{SetAUGTitle|J3 connector wiring}}{{ArgonManualNav}}Argon's J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake.
 
==Pin-out==
 
==Pin-out==
 
{| class="wikitable"
 
{| class="wikitable"
Line 16: Line 16:
 
Brake output is optional and may be left unconnected if brake is not present in the axis.
 
Brake output is optional and may be left unconnected if brake is not present in the axis.
 
[[File:Argonwiringoverview.png|800px]]
 
[[File:Argonwiringoverview.png|800px]]
 +
[[Category:Argon wiring]]

Latest revision as of 13:44, 6 December 2013

Argon's J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake.

Pin-out[edit | edit source]

Pin # Pin name Description Connection
1 BK Motor brake output If motor has a 24V solenoid brake, connect brake between BK and V+
2 V+ 24V supply positive input Connect to 24V PSU +
3 V- 24V supply ground, on J1, J2.x and J5 connectors tied to GND Connect to 24V PSU -

24VDC typical current consumption is between 0.1 - 0.7ADC depending on how much current is drawn by feedback device and an optional motor brake.

Wiring guide[edit | edit source]

Brake output is optional and may be left unconnected if brake is not present in the axis. Argonwiringoverview.png