Difference between revisions of "IONI firmware releases"
[checked revision] | [checked revision] |
(43 intermediate revisions by 2 users not shown) | |||
Line 381: | Line 381: | ||
|Low | |Low | ||
+ | |- | ||
+ | |1.7.5 | ||
+ | [[Media:IONIFW-1.7.5.gdf|download]] | ||
+ | |8.5.2018 | ||
+ | |10705 | ||
+ | | | ||
+ | *Fixes | ||
+ | **Fix an issue SimpleMotion watchdog feature (SMP_FAULT_BEHAVIOR, when enabled) could trigger without valid reason and cause communication error. | ||
+ | |This fixes connection issues especially when using smFastUpdateCycle function with SM bus watchdog enabled (i.e. temporary loss of connection & consequent position loss in SimuCUBE usage) | ||
+ | |Medium | ||
+ | |||
+ | |||
+ | |- | ||
+ | |1.7.6 | ||
+ | [[Media:IONIFW-1.7.6.gdf|download]] | ||
+ | |22.5.2018 | ||
+ | |10706 | ||
+ | | | ||
+ | *Fixes | ||
+ | **Fix an issue where position feedback value could be non-zero after drive initialization when using SinCos feedback device. The bug first appeared on 1.7.4. | ||
+ | | | ||
+ | |Medium | ||
+ | |||
+ | |- | ||
+ | |1.7.7 | ||
+ | [[Media:IONIFW-1.7.7.gdf|download]] | ||
+ | |20.6.2018 | ||
+ | |10707 | ||
+ | | | ||
+ | *Fixes | ||
+ | **Fix regenerative overvoltage fault issue that occurred with certain motors in SimuCUBE mode | ||
+ | | | ||
+ | |Low | ||
+ | |||
+ | |||
+ | |- | ||
+ | |1.7.9 | ||
+ | [[Media:IONIFW-1.7.9.gdf|download]] | ||
+ | |11.2.2019 | ||
+ | |10709 | ||
+ | | | ||
+ | * Improvements | ||
+ | ** Regenerative algorithm improvement, provides solution to an over voltage fault in certain conditions for SimuCUBE users | ||
+ | ** Removed time delay from [[STO]] event to mechanical brake release, brake is now released immediately after STO | ||
+ | *Fixes | ||
+ | **Resolved open-loop stepping motor instability issue when both {{param|AXI}} and {{param|FBI}} were enabled | ||
+ | **Reduced SinCos encoder signal voltage level requirement helping SinCos encoder to successfully operate with all known SinCos encoders. Affected users will yield improved encoder precision with this fix. | ||
+ | | | ||
+ | |Low | ||
+ | |||
+ | |- | ||
+ | |1.7.10 | ||
+ | [[Media:IONIFW-1.7.10.gdf|download]] | ||
+ | |31.5.2019 | ||
+ | |10710 | ||
+ | | | ||
+ | * New fetures | ||
+ | ** Implemented FAST_UPDATE_CYCLE_FORMAT_ALT3 | ||
+ | * Improvements | ||
+ | ** Setting new motor current limit will now take effect immediately instead of being slowed down by a smooth tansition function | ||
+ | *Fixes | ||
+ | ** Fix BiSS encoder readout error occurring on some BiSS encoder models right after motor [[Phasing a.k.a. phase search]] sequence | ||
+ | ** Fix [[I²t protection]] ({{param|MTC}} was not having any effect in earlier 1.7 versions) | ||
+ | ** Fix erroneous overriding of SMP subpacket access status (per command status was always 0=ACK even when writing invalid value to parameter, only cumulative status indicated the access error). This may affect specific case of error checking in some SimpleMotion apps that are also incorrectly accessing parameters that do not exist in drive (no such cases where such error checking method is used are known). | ||
+ | | | ||
+ | |Low | ||
+ | |||
+ | |||
+ | |- | ||
+ | |1.7.11 | ||
+ | [[Media:IONIFW-1.7.11.gdf|download]] | ||
+ | |9.1.2020 | ||
+ | |10711 | ||
+ | | | ||
+ | * Improvements | ||
+ | ** Make setpoint smoothing filter {{param|CIS}} to have effect also in velocity control mode (before applid only to position control) | ||
+ | ** Reset motor [[I²t protection]] when motor current limits {{param|MCC}} or {{param|MMC}} are changed (except not reset if {{param|CEI}} is set to Simucube mode). This prevents unnecessary overcurrent error with fault ID 140600 in special cases. | ||
+ | *Fixes | ||
+ | ** Added small delay between the initialization of serial encoder and the first encoder read to prevent errors with some BiSS/SSI encoder types | ||
+ | ** Fix an glitch where position offset could be accumulated after fast control mode changes | ||
+ | | | ||
+ | |Low | ||
+ | |||
+ | |- | ||
+ | |1.7.12 | ||
+ | download removed, use later version instead | ||
+ | |21.1.2020 | ||
+ | |10712 | ||
+ | | | ||
+ | * Improvements | ||
+ | ** Reason for drive delaying initialization (wait for proper conditions) is now displayed as [[Fault location]] number | ||
+ | *Fixes | ||
+ | ** Fix the still occasionally occurring 140600 fault location of 1.7.11 version due to motor I²t protection | ||
+ | | | ||
+ | |Low | ||
+ | |||
+ | |- | ||
+ | |1.7.14 | ||
+ | download removed, use later version instead | ||
+ | |14.4.2020 | ||
+ | |10714 | ||
+ | | | ||
+ | * New features | ||
+ | ** Simucube Static force reduction filter ported from Simucube 2 (will be added in upcoming Simucube 1 software release) | ||
+ | * New developer features | ||
+ | ** Added new SMP_RAW_QUADRATURE_ENCODER_POSITION_FB SimpleMotion parameter to allow reading quadrature encoder in all operating modes | ||
+ | ** Added support for 24 bit ALT4 fast update cycle format (Simucube specific) | ||
+ | * System improvements | ||
+ | ** Added on-the-fly stack memory usage monitoring to enhance firmware ruggedness | ||
+ | ** Recalibrated stack memory pool sizes | ||
+ | ** Updated FreeRTOS kernel | ||
+ | ** Updated to GCC 9 code compilation | ||
+ | *Fixes | ||
+ | ** Fix an bug that caused 1.7.12 firmware to freeze at initialization with specific feedback device configuration. | ||
+ | ** Fix GPO3 pin (fault output) polarity, now it active fault sets GPO3 to logic low as specified | ||
+ | |The fixed bug might be related to stack memory usage and may affect also other cases. Upgrade is recommended for all users experiencing any unexpected drive behavior. | ||
+ | |Medium | ||
+ | |||
+ | |- | ||
+ | |1.7.15 | ||
+ | [[Media:IONIFW-1.7.15.gdf|download]] | ||
+ | |17.4.2020 | ||
+ | |10715 | ||
+ | | | ||
+ | *Fixed bugs present only in V1.7.14 | ||
+ | ** Fix erroneous current scale of IONI Pro HC model | ||
+ | ** Fix occasional triggering of newly added 192111 [[fault location]] (stack memory usage monitoring) | ||
+ | ** Fix occasional changing of SimpleMotion address after drive restart | ||
+ | |This is mandatory upgrade for 1.7.14 users. | ||
+ | |High | ||
+ | |||
+ | |- | ||
+ | |1.7.16 | ||
+ | [[Media:IONIFW-1.7.16.gdf|download]] | ||
+ | |14.5.2020 | ||
+ | |10716 | ||
+ | | | ||
+ | *Fixes | ||
+ | ** Fix potentially malfunctioning of GPO1 & GPO2 pins | ||
+ | | | ||
+ | |Medium | ||
+ | |||
+ | |||
+ | |- | ||
+ | |1.7.18 | ||
+ | [[Media:IONIFW-1.7.18.gdf|download]] | ||
+ | |11.11.2020 | ||
+ | |10718 | ||
+ | | | ||
+ | *Fixes | ||
+ | ** Added missing status update of STAT_QUICK_STOP_ACTIVE | ||
+ | ** Fixed Simucube wheel offset problem that made it difficult to center the wheel during the start-up. Affects only users with incremental encoders (not BiSS/absolute encoder users). | ||
+ | | | ||
+ | |Low | ||
+ | |||
+ | |- | ||
+ | |1.7.20 | ||
+ | [[Media:IONIFW-1.7.20.gdf|download]] | ||
+ | |14.6.2021 | ||
+ | |10720 | ||
+ | | | ||
+ | *Improvements | ||
+ | ** Improved response time and smoothness of commutation angle calculation. Might affect (namely improve) torque control dynamics performance in some cases. | ||
+ | ** If {{param|FBD}} selection is "Serial data encoder", then home switch inputs are remapped to CHA and CHB input pins from LIM+ and LIM- pins. This change allows connecting limit switches with SSI and BiSS encoders, which was not supported before. | ||
+ | *** In this FBD mode, CHA is the positive limit switch input, and CHB the negative limit switch input. | ||
+ | |Motor tuning may be affected by this version so re-tuning motor may be beneficial. However it is unlikely to be necessary, or yield significant improvement. | ||
+ | |Low | ||
+ | |||
+ | |- | ||
+ | |1.7.21 | ||
+ | [[Media:IONIFW-1.7.21.gdf|download]] | ||
+ | |14.1.2022 | ||
+ | |10721 | ||
+ | | | ||
+ | *Fixes | ||
+ | ** Fixed a bug that caused motor to jump back to power-on position right after STO deactivation if following conditions are met: | ||
+ | *** position control mode is active | ||
+ | *** STO was pressed during power-on | ||
+ | *** and motor was externally moved before initialization while drive logic voltage is on | ||
+ | *** motor does not use phasing procedure (DC motor or commutation sensor enabled) | ||
+ | *** bug cause: encoder was not reset at init in above motor configuration | ||
+ | |||
+ | * '''Do not install this in Simucube use case''' | ||
+ | ** An issue has been noted with this firmware version with Torque mode in Simucube use, when an absolute encoder (such as BiSS-C) is used. We recommend to use 1.7.20 release in Simucube. | ||
+ | | | ||
+ | |Low. (High for use cases where this bug might cause danger). | ||
+ | |||
+ | |||
+ | |- | ||
+ | |1.8.1 | ||
+ | [[Media:IONIFW-1.8.1.gdf|download]] | ||
+ | |11.2.2025 | ||
+ | |10801 | ||
+ | | | ||
+ | *New features | ||
+ | ** Simucube 2's Reconstruction filter V2 added. Requires also Simucube 1 firmware update to use the new feature. | ||
+ | *Fixes to V1.7.21 | ||
+ | ** Fixed an issue affecting some BiSS encoders (that was caused by slightly increased BiSS readout clock rate). | ||
+ | ** Fixed false overvelocity fault that occurred after initialization with specific configuration settings. | ||
+ | |Recommended update for all users | ||
+ | |Low | ||
|} | |} | ||
Latest revision as of 09:27, 11 February 2025
This page lists the official firmware releases of the IONI Servo Drive and the change log.
Contents
[hide]Upgrading firmware
Read instructions from Granity user guide/Uploading a firmware.
Releases
- Glossary
- Firmware release version - a firmware file with .gdf name extension that contains the firmware firmware
- Version code - the version shown in Granity
- Change log - the list of changes made since the previous package version.
- Remarks - Notes
Firmware release version | Date | Version code | Change log | Remarks | Criticality |
---|---|---|---|---|---|
1.0.0 | 15.3.2015 | 1050 |
|
||
1.0.1 | 19.3.2015 | 1052 |
|
Medium | |
1.0.2 | 11.4.2015 | 1054 |
|
Important upgrade due to overcurrent protection fix and phasing current calcuation fix. | Very high |
1.0.3 | 12.4.2015 | 1056 |
|
Medium | |
1.0.4 | 13.4.2015 | 1058 |
|
Medium | |
1.1.0 download | 15.4.2015 | 1060 |
|
The new feature requires Granity V 1.6.0 | Medium (High for DC motor users) |
1.2.0 download | 4.5.2015 | 1062 |
|
The SinCos support requires Granity V 1.7.0
Note: if acceleration or velocity feed-forward gain parameters are non-zero, re-tune the AFF and VFF gains after upgrade! |
Medium |
1.2.1 download | 3.6.2015 | 1064 |
|
Note: adjust KVP, KPP and VFF values after upgrade! See change log for details. | Low |
1.2.2 download | 23.6.2015 | 1068 |
|
Low | |
1.2.3 download | 15.7.2015 | 1070 |
|
Low | |
1.3.0 download | 2.11.2015 | 1080 |
|
Requires Granity V 1.9.0 | Low |
1.3.1 download | 25.11.2015 | 1082 |
|
Low | |
1.4.0 download | 31.12.2015 | 1084 |
|
|
Medium |
1.5.0 download | 8.5.2016 | 1092 |
|
|
Low |
1.5.1 download | 6.6.2016 | 1094 |
|
Medium | |
1.5.2 | 4.8.2016 | 1096 |
|
In open loop stepper mode, update KVI and KPP parameters according to page Using stepping motor with IONI | Medium |
1.5.3 download | 11.8.2016 | 1098 |
|
See also notes of 1.5.2. | Medium |
1.5.4 download | 8.9.2016 | 1100 |
|
It may be necessary to decrease FUV and/or increase FOV parameter values to make drive initialize as the new changes requires 2% safety headroom for these values versus actual supply voltage.
I.e. for 48.0V supply voltage, the FUV value should be less than 48*0.98=47V and FOV should be greater than 48/0.98=49V. In practice, make allowed voltage range at least 0.5V wider to allow supply voltage variation, like FUV=46.5V and FOV=49.5V or greater. For more information, see Configuring drive voltage limits FUV and FOV |
Medium |
1.5.5 download | 19.12.2016 | 1102 |
|
Medium | |
1.5.6 download | 16.1.2017 | 1104 |
|
Maximum FOC setting is still safe value for drive. | Low |
1.5.8 download | 14.2.2017 | 1108 |
|
This, or later version is required for drives manufactured after 1.2017 due to minor hardware change. Installing older FW version on such device will cause update error and requires re-update. | Low |
1.6.0 download | 3.8.2017 | 10600 |
|
|
Low |
1.6.1 download | 30.8.2017 | 10601 |
|
Low | |
1.7.0
download removed, use 1.7.1 |
30.1.2018 | 10700 |
|
Force enable drive button in Granity older than than 1.14 will not have any effect due to SimpleMotion changes.
Update: 1.7.0 contains couple of new bugs (see 1.7.1 notes). Upgrade to 1.7.1 recommended. |
Medium |
1.7.1 | 14.2.2018 | 10701 |
|
Medium | |
1.7.2 | 27.2.2018 | 10702 |
|
Low | |
1.7.4 | 3.5.2018 | 10704 |
|
Low | |
1.7.5 | 8.5.2018 | 10705 |
|
This fixes connection issues especially when using smFastUpdateCycle function with SM bus watchdog enabled (i.e. temporary loss of connection & consequent position loss in SimuCUBE usage) | Medium
|
1.7.6 | 22.5.2018 | 10706 |
|
Medium | |
1.7.7 | 20.6.2018 | 10707 |
|
Low
| |
1.7.9 | 11.2.2019 | 10709 |
|
Low | |
1.7.10 | 31.5.2019 | 10710 |
|
Low
| |
1.7.11 | 9.1.2020 | 10711 |
|
Low | |
1.7.12
download removed, use later version instead |
21.1.2020 | 10712 |
|
Low | |
1.7.14
download removed, use later version instead |
14.4.2020 | 10714 |
|
The fixed bug might be related to stack memory usage and may affect also other cases. Upgrade is recommended for all users experiencing any unexpected drive behavior. | Medium |
1.7.15 | 17.4.2020 | 10715 |
|
This is mandatory upgrade for 1.7.14 users. | High |
1.7.16 | 14.5.2020 | 10716 |
|
Medium
| |
1.7.18 | 11.11.2020 | 10718 |
|
Low | |
1.7.20 | 14.6.2021 | 10720 |
|
Motor tuning may be affected by this version so re-tuning motor may be beneficial. However it is unlikely to be necessary, or yield significant improvement. | Low |
1.7.21 | 14.1.2022 | 10721 |
|
Low. (High for use cases where this bug might cause danger).
| |
1.8.1 | 11.2.2025 | 10801 |
|
Recommended update for all users | Low |
Beta releases
Version | Date | Version code | Change log | Remarks |
---|---|---|---|---|
No beta releases at the moment | - | - | - | - |
![]() | As firmware changes may affect the behavior of the drive/motor sometimes in unexpected ways, pay attention to machine safety and be prepared for unexpected motion. It is a good safety practice to disconnect motor shaft before upgrading and during testing. If problems encountered, please report us. We will fix firmware issues as first priority task. |
Known bugs & limitations
Bugs that are known in the latest FW revision:
- Setpoint smoothing does not have effect in velocity or torque modes (only position mode)
- Install firmware button in Granity does not always have effect with IONICUBE (4 axis). Workaround: insert jumper in position 3 of JP10 and restart 24V power to force devices in firmware upgrade mode. This minor issue affects only first production run IONI drives shipped around April 2015 to June 2015.
- Overcurrent fault with Fault location 402001 may cause false alarms on some setups. Improvements in future firwmare are planned. If problem occurs, as workaround set Over current toleranceFOC to Maximum.
Credits, copyrights and third party software
Several fantastic pieces of open-source software have helped get IONI firmware to where it is today. For fur list of credits, see Third-party licenses.