Difference between revisions of "Argon user guide/J3 connector wiring"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(Created page with "Argon's J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake. ==Pin-out== {| class="wikitable" |- ! P...") |
|||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | Argon's J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake. | + | {{SetAUGTitle|J3 connector wiring}}{{ArgonManualNav}}Argon's J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake. |
==Pin-out== | ==Pin-out== | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 16: | Line 16: | ||
Brake output is optional and may be left unconnected if brake is not present in the axis. | Brake output is optional and may be left unconnected if brake is not present in the axis. | ||
[[File:Argonwiringoverview.png|800px]] | [[File:Argonwiringoverview.png|800px]] | ||
+ | [[Category:Argon wiring]] |
Latest revision as of 13:44, 6 December 2013
Argon's J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake.Pin-out[edit | edit source]
Pin # | Pin name | Description | Connection |
---|---|---|---|
1 | BK | Motor brake output | If motor has a 24V solenoid brake, connect brake between BK and V+ |
2 | V+ | 24V supply positive input | Connect to 24V PSU + |
3 | V- | 24V supply ground, on J1, J2.x and J5 connectors tied to GND | Connect to 24V PSU - |
24VDC typical current consumption is between 0.1 - 0.7ADC depending on how much current is drawn by feedback device and an optional motor brake.
Wiring guide[edit | edit source]
Brake output is optional and may be left unconnected if brake is not present in the axis.