Difference between revisions of "Argon specifications"
[checked revision] | [checked revision] |
m (Protected "Argon specifications" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
(→Safety) |
||
Line 281: | Line 281: | ||
*MOV based transient overvoltage protection | *MOV based transient overvoltage protection | ||
*Earth leakage current typ. < 0.5 mA | *Earth leakage current typ. < 0.5 mA | ||
− | *ESD protection on all pins | + | *ESD, short circuit, reverse polarity protection on all pins |
*Surge protection on AC & DC power inputs | *Surge protection on AC & DC power inputs | ||
|| Galvanic isolation on J1, J2, J3 and J5 connectors against J4 with live AC mains voltages | || Galvanic isolation on J1, J2, J3 and J5 connectors against J4 with live AC mains voltages |
Revision as of 17:51, 21 October 2013
This page lists official functional, electrical and physical specifications of the ARGON Servo Drive.Main functionality
Function | Description |
---|---|
Servo motor drive | Closed loop control of various types of servo motors by sinusoidal field oriented control with dead-time distortion correction and high dynamic range torque control.
|
Control modes |
|
Closed loop | Cascaded control loops (PIV):
Dual-loop feedback support planned as firmware upgrade |
Feed-forwards | Feed-forwards working in velocity & position control modes:
|
Homing | Integrated homing function for position control mode:
|
Setpoint signal | See setpoint signal / reference inputs list |
Feedback devices | See feedback devices list |
Safety |
|
Protections |
|
Commissioning |
|
Approvals | CE (LVD & EMC) |
Mechanical
Property | Value | Units |
---|---|---|
Dimensions (with wall mounting tabs)¹ | 51×197×127 (W×H×D) | mm |
Dimensions (excluding wall mounting tabs)¹ | 51×177×127 (W×H×D) | mm |
Weight | 0.88 | kg |
Case materials | Steel (cover), aluminum (heat sink) |
¹) Wall mounting tabs are fixed part of enclosure
Environment
Property | Value | Units |
---|---|---|
Operating temperature | 10-70 | °C |
Storage temperature | -30-90 | °C |
Humidity | 0-95 non-condensing | % |
Power dissipation | 2-100¹ | W |
¹) Power dissipation is output current and input voltage related.
Power supply
Supply² | Input voltage | Input current typ | Input current max |
---|---|---|---|
Logic power | 24 VDC +/- 10% | 0.1 - 0.4 A | 0.5 A |
Motor power³ | 85 - 264 VAC 50/60 Hz | 0 - 15 A¹ | 26 A¹ |
84 - 380 VDC | 0 - 15 A¹ | 26 A¹ |
¹) Estimating true current or power consumption based on this table may be difficult as current demand typically varies greatly and and almost completely depends on motor load conditions.
²) Both logic and motor supplies are required.
³) Features internal inrush current limiter
Motor output
Property | Value | Units | Remarks |
---|---|---|---|
Supported motors | AC, BLDC, DC, Linear | Permanent magnet motors only | |
Continuous output current | 0-10 | A (peak value of sine) | User settable limit |
Peak output current | 0-15 | A (peak value of sine) | Duration 1 sec, then returned to continuous limit. User settable current limit. |
Maximum effective motor phase output voltage | Max 88% of input AC supply voltage AC or 124% DC. | I.e. for 230 VAC drive supply, max motor output is 202 VAC (AC/BLDC/Linear) or 285 VDC (brush DC). | |
Switching frequency | 17.5 | kHz | |
Maximum modulation depth | 88 | % | Maximum effective output is 88% of HV DC bus voltage. |
Torque control bandwidth (typ.) | 1-3.3 | kHz | Motor coil dependent |
Torque control cycle time | 57.1 | µs | |
Position & velocity control cycle time | 400 | µs | |
Power conversion efficiency | 90-95 | % | Under typical conditions |
Motor inductance range @ 230 VAC | 1.4-25 | mH | |
Motor inductance range @ 115 VAC | 0.7-25 | mH | |
Motor power range | 0.05 - 1.5 | kW | |
AC commutation frequency | 0-400 | Hz |
Regenerative resistor
Property | Value | Units |
---|---|---|
Maximum current | 6 | A |
Series fuse | 8 | A |
Minimum allowed resistance @ 230 VAC supply | 63 | Ω |
Minimum allowed resistance @ 115 VAC supply | 35 | Ω |
Resistor power dissipation | 0-2400¹ | W |
¹) Power dissipation depends on how much system's kinetic energy is directed to the resistor
Feedback devices
Status of feedback device support
Feedback device type | Status | Electrical interface |
---|---|---|
Quadrature incremental encoder | Standard feature | Differential 3-5.5V (RS422), Single ended 3-5.5V (CMOS,TTL,open collector) |
Hall sensors | Standard feature | Single ended 3-5.5V (CMOS,TTL,open collector). Differential signals accepted. |
Analog SinCos encoder | Under development¹ | 1 V p-p, 12 bits sampling |
Resolver/synchro | Under development¹ | 10 kHz excitation |
Serial SSI encoder | Planned¹ | RS422/RS485 |
Serial BiSS encoder | Planned¹ | RS422/RS485 |
Tachogenerator | Planned¹ |
¹) Supported already by hardware, usage possible after firmware upgrade
Quadrature encoder electrical properties
Property | Value | Units | Remarks |
---|---|---|---|
Encoder count rate | 0-4 | MHz | After 4x decoding, digitally filtered |
Supply voltage | 4.8-5.2 | V | Supplied from drive |
Supply current | 0-500 | mA | Supplied from drive |
Setpoint signal / reference inputs
Setpoint signal type | Status | Electrical interface |
---|---|---|
Analog | Standard feature | Up to +/-10V or any lower range |
Pulse and direction | Standard feature | Up to 4 MHz step rate, 5V signaling |
Quadrature | Standard feature | Up to 4 MHz count rate, 5V signaling |
PWM | Standard feature | 3-30 kHz PWM carrier frequency |
Serial communication | Standard feature | SimpleMotion V2 RS485 based real-time serial bus with open source SDK |
Stand-alone operation or custom setpoint signal | User implementable | May be implemented in the Argon open source firmware |
EtherCAT | Planned | Realized with add-on board |
Inputs / outputs
List of I/O's
- Isolated digital inputs (4 channels) - used for limit & home switches and clear faults signal ¹
- Isolated digital outputs (4 channels) - used for status indication ¹
- Differential analog inputs (2 channels) - used as Analog setpoint ¹
- Differential digital inputs (2 channels) - used for pulse/direction or second encoder ¹
- Digital inputs (3 channels) - used for safe torque off and drive enable
- Digital output (1 channel) - used for motor solenoid brake
¹) Functions may be altered by modifying the Argon open source firmware
Electrical characteristics
For detailed specifications, see I/O electrical interfacing and pinout & wiring.
Property | Typical value | Maximum rating | Units |
---|---|---|---|
Protections (all I/O lines) | overvoltage, ESD, short circuit, reverse polarity | ||
Isolated digital input (GPIx) logic 1 voltage | 3-24 | 25.5 | V |
Isolated digital input (GPIx) logic 0 voltage | 0-1.3 | V | |
Isolated digital output (GPOx) voltage | 0-24 | 25.5 | V |
Isolated digital output (GPOx) current | 0-10 | 10 | mA |
High speed digital input (HSINx) voltage range | 2.7-5.5 | 6.0 | V |
Analog input input (ANAINx) voltage range | ±10 | ±25 vs GND | V |
Analog input input (ANAINx) resolution | 12 | bits | |
Enable input input logic 1 voltage | 20-24 | 25.5 | V |
STO input input logic 1 voltage | 20-24 | 25.5 | V |
Motor brake voltage | 12-24 | 25.5 | V |
Motor brake load current | 0-0.5 | 0.7 | A |
¹) Power dissipation is output current and input voltage related.
Communication
Property | Value | Units |
---|---|---|
Communication protocol | SimpleMotion V2 | |
Default bitrate | 460800 | BPS |
Maximum number of Argon devices chained in a single bus | 15 | pcs |
Command throughput | Up to 10000 | Commands/s |
Safety
Feature | Properties | Remarks |
---|---|---|
Safe torque off |
|
STO1 safe up to 6 A RMS input current |
Control error detection |
|
|
Electrical safety |
|
Galvanic isolation on J1, J2, J3 and J5 connectors against J4 with live AC mains voltages |
Overload safety |
|
Warnings