Difference between revisions of "SimuCUBE technical specifications"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
(Created page with "== Electrical == Please refer to IONI specifications for detailed information of the different IONI servo drive models. == Mechanical == {{picturebox|Simucube_dimensi...")
 
(Mechanical)
 
(26 intermediate revisions by 3 users not shown)
Line 1: Line 1:
== Electrical ==
+
{{SimucubeManualNav}}
Please refer to [[IONI specifications]] for detailed information of the different [[IONI]] servo drive models.
+
 
+
 
== Mechanical ==
 
== Mechanical ==
{{picturebox|Simucube_dimensions.png|800px|caption=SimuCUBE dimensions.}}
+
[[file:Simucube_dimensions.png|thumb|left|360px|Dimension drawing]]
  
== Enviroment ==
+
{| class="wikitable"
 +
!Dimension
 +
!Length
 +
|-
 +
|Width
 +
|160 mm
 +
|-
 +
|Depth
 +
|87.5 mm
 +
|-
 +
|Height
 +
|< 50 mm (with IONI drive inserted)
 +
|}
 +
3D file (simplified):
 +
* [[media:Simucube_r004_simplified_full.zip|IGS file.]]
 +
2D PDF and DXF files of the acrylic cases can be found here:
 +
* [[media:simucube_small_case_pdf_dxf.zip|Small (320 W PSU) acrylic case 2d files, PDF and DXF.]]
 +
* [[media:simucube_big_case_pdf_dxf.zip|Big (480/720 W PSU) acrylic case 2d files, PDF and DXF.]]
 +
 
 +
In case of DIY project to cut the case acrylic components, the acrylic sheet thickness is 4 mm.
 +
 
 +
== Environmental ==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 16: Line 35:
 
| Humidity || 0-95 non-condensing || %
 
| Humidity || 0-95 non-condensing || %
 
|}
 
|}
 +
Note: on board IONI drive will require forced air flow cooling above 7 A output drive current.
  
== Power supply ==
+
== Electrical ==
 +
=== Power supply ===
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Supply !! Input voltage  !! Input current typ !! Input current max
+
! Input voltage  !! Input current when idle !! Input current max
 
|-
 
|-
| Motor power || 5 - 56 VDC<sup>1</sup> ||colspan=2| Sum of current consumption of on-board IONI drive
+
| 20 - 49 VDC<sup>1</sup> || Typically < 0.4 A
 +
|Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply.
 
|}
 
|}
<sup>1</sup>) Possible to use from 5 VDC upwards, however short circuit protection feature of IONI drive is lost below 12 VDC.
+
Notes:
 +
* SimuCUBE has an input diode for reverse input voltage protection
 +
* Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable
 +
 
 +
===I/O===
 +
All back face I/O connector pins of SimuCUBE are ESD protected.
 +
{| class="wikitable"
 +
|-
 +
! Property !! Connector/pins !! Value !! Unit
 +
|-
 +
| Button connection || X12A/X12B || Switch connected between input pin and GND pin || 
 +
|-
 +
| Button input pull-up voltage || X12A/X12B || 3.3 || V
 +
|-
 +
| Button input pull-up resistance || X12A/X12B || 3.3 || kOhm
 +
|-
 +
| Analog input voltage range || X11A/X11B || 0-3.3 || V
 +
|-
 +
| Analog input impedance || X11A/X11B || > 10 || kOhm
 +
|-
 +
| Analog input resolution || X11A/X11B || 12 || bits
 +
|-
 +
| E-stop / [[Safe torque off]] input connection || X1 pins 6-7 || Normally closed (NC) switch connected between X1 pins 6 and 7 ||
 +
|}
 +
 
 +
== Motor control ==
 +
SimuCUBE motor control is based on a [[IONI Servo & Stepper Drive]] that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to [[IONI specifications]] for details about:
 +
* Output current ratings
 +
* Supported [[Feedback devices]]
 +
* Heat dissipation & cooling
 +
* Fault protections
  
SimuCUBE has an input diode for reverse input voltage protection. It also enables the use of switching mode power supplies that would not be able to sink current.
+
[[Category:SimuCUBE]]
 +
[[Category:SimuCUBE_user_guide]]

Latest revision as of 07:37, 1 July 2022

Mechanical[edit | edit source]

Dimension drawing
Dimension Length
Width 160 mm
Depth 87.5 mm
Height < 50 mm (with IONI drive inserted)

3D file (simplified):

2D PDF and DXF files of the acrylic cases can be found here:

In case of DIY project to cut the case acrylic components, the acrylic sheet thickness is 4 mm.

Environmental[edit | edit source]

Property Value Units
Operating temperature 10-70 °C
Storage temperature -30-90 °C
Humidity 0-95 non-condensing  %

Note: on board IONI drive will require forced air flow cooling above 7 A output drive current.

Electrical[edit | edit source]

Power supply[edit | edit source]

Input voltage Input current when idle Input current max
20 - 49 VDC1 Typically < 0.4 A Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply.

Notes:

  • SimuCUBE has an input diode for reverse input voltage protection
  • Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable

I/O[edit | edit source]

All back face I/O connector pins of SimuCUBE are ESD protected.

Property Connector/pins Value Unit
Button connection X12A/X12B Switch connected between input pin and GND pin
Button input pull-up voltage X12A/X12B 3.3 V
Button input pull-up resistance X12A/X12B 3.3 kOhm
Analog input voltage range X11A/X11B 0-3.3 V
Analog input impedance X11A/X11B > 10 kOhm
Analog input resolution X11A/X11B 12 bits
E-stop / Safe torque off input connection X1 pins 6-7 Normally closed (NC) switch connected between X1 pins 6 and 7

Motor control[edit | edit source]

SimuCUBE motor control is based on a IONI Servo & Stepper Drive that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to IONI specifications for details about:

  • Output current ratings
  • Supported Feedback devices
  • Heat dissipation & cooling
  • Fault protections