Difference between revisions of "SimuCUBE technical specifications"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
(Mechanical)
 
(21 intermediate revisions by 3 users not shown)
Line 1: Line 1:
== Electrical ==
+
{{SimucubeManualNav}}
Please refer to [[IONI specifications]] for detailed information of the different [[IONI]] servo drive models.
+
 
+
 
== Mechanical ==
 
== Mechanical ==
{{picturebox|Simucube_dimensions.png|800px|caption=SimuCUBE dimensions.}}
+
[[file:Simucube_dimensions.png|thumb|left|360px|Dimension drawing]]
  
== Enviroment ==
+
{| class="wikitable"
 +
!Dimension
 +
!Length
 +
|-
 +
|Width
 +
|160 mm
 +
|-
 +
|Depth
 +
|87.5 mm
 +
|-
 +
|Height
 +
|< 50 mm (with IONI drive inserted)
 +
|}
 +
3D file (simplified):
 +
* [[media:Simucube_r004_simplified_full.zip|IGS file.]]
 +
2D PDF and DXF files of the acrylic cases can be found here:
 +
* [[media:simucube_small_case_pdf_dxf.zip|Small (320 W PSU) acrylic case 2d files, PDF and DXF.]]
 +
* [[media:simucube_big_case_pdf_dxf.zip|Big (480/720 W PSU) acrylic case 2d files, PDF and DXF.]]
 +
 
 +
In case of DIY project to cut the case acrylic components, the acrylic sheet thickness is 4 mm.
 +
 
 +
== Environmental ==
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 16: Line 35:
 
| Humidity || 0-95 non-condensing || %
 
| Humidity || 0-95 non-condensing || %
 
|}
 
|}
 +
Note: on board IONI drive will require forced air flow cooling above 7 A output drive current.
  
== Power supply ==
+
== Electrical ==
 +
=== Power supply ===
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Supply !! Input voltage  !! Input current typ !! Input current max
+
! Input voltage  !! Input current when idle !! Input current max
 
|-
 
|-
| Motor power || 5 - 56 VDC<sup>1</sup> ||colspan=2| Sum of current consumption of on-board IONI drive
+
| 20 - 49 VDC<sup>1</sup> || Typically < 0.4 A
 +
|Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply.
 
|}
 
|}
<sup>1</sup>) Possible to use from 5 VDC upwards, however short circuit protection feature of IONI drive is lost below 12 VDC.
+
Notes:
 +
* SimuCUBE has an input diode for reverse input voltage protection
 +
* Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable
  
SimuCUBE has an input diode for reverse input voltage protection. It also enables the use of switching mode power supplies that would not be able to sink current.
+
===I/O===
 +
All back face I/O connector pins of SimuCUBE are ESD protected.
 +
{| class="wikitable"
 +
|-
 +
! Property !! Connector/pins !! Value !! Unit
 +
|-
 +
| Button connection || X12A/X12B || Switch connected between input pin and GND pin || 
 +
|-
 +
| Button input pull-up voltage || X12A/X12B || 3.3 || V
 +
|-
 +
| Button input pull-up resistance || X12A/X12B || 3.3 || kOhm
 +
|-
 +
| Analog input voltage range || X11A/X11B || 0-3.3 || V
 +
|-
 +
| Analog input impedance || X11A/X11B || > 10 || kOhm
 +
|-
 +
| Analog input resolution || X11A/X11B || 12 || bits
 +
|-
 +
| E-stop / [[Safe torque off]] input connection || X1 pins 6-7 || Normally closed (NC) switch connected between X1 pins 6 and 7 ||
 +
|}
  
{{next|[[SimuCUBE user guide/SimuCUBE pinout|Pinout]]}}
+
== Motor control ==
 +
SimuCUBE motor control is based on a [[IONI Servo & Stepper Drive]] that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to [[IONI specifications]] for details about:
 +
* Output current ratings
 +
* Supported [[Feedback devices]]
 +
* Heat dissipation & cooling
 +
* Fault protections
  
 
[[Category:SimuCUBE]]
 
[[Category:SimuCUBE]]
 
[[Category:SimuCUBE_user_guide]]
 
[[Category:SimuCUBE_user_guide]]

Latest revision as of 07:37, 1 July 2022

Mechanical[edit | edit source]

Dimension drawing
Dimension Length
Width 160 mm
Depth 87.5 mm
Height < 50 mm (with IONI drive inserted)

3D file (simplified):

2D PDF and DXF files of the acrylic cases can be found here:

In case of DIY project to cut the case acrylic components, the acrylic sheet thickness is 4 mm.

Environmental[edit | edit source]

Property Value Units
Operating temperature 10-70 °C
Storage temperature -30-90 °C
Humidity 0-95 non-condensing  %

Note: on board IONI drive will require forced air flow cooling above 7 A output drive current.

Electrical[edit | edit source]

Power supply[edit | edit source]

Input voltage Input current when idle Input current max
20 - 49 VDC1 Typically < 0.4 A Depends on power driven to motor. Up to about 25 A peak consumption is possible. In typical cases 10A @ 48V is sufficient supply.

Notes:

  • SimuCUBE has an input diode for reverse input voltage protection
  • Switching mode power supply (SMPS) and linear transformer based power supplies are directly suitable

I/O[edit | edit source]

All back face I/O connector pins of SimuCUBE are ESD protected.

Property Connector/pins Value Unit
Button connection X12A/X12B Switch connected between input pin and GND pin
Button input pull-up voltage X12A/X12B 3.3 V
Button input pull-up resistance X12A/X12B 3.3 kOhm
Analog input voltage range X11A/X11B 0-3.3 V
Analog input impedance X11A/X11B > 10 kOhm
Analog input resolution X11A/X11B 12 bits
E-stop / Safe torque off input connection X1 pins 6-7 Normally closed (NC) switch connected between X1 pins 6 and 7

Motor control[edit | edit source]

SimuCUBE motor control is based on a IONI Servo & Stepper Drive that plugs on the provided socket. All motor control specifications are identical to IONI drive specifications. Refer to IONI specifications for details about:

  • Output current ratings
  • Supported Feedback devices
  • Heat dissipation & cooling
  • Fault protections