Difference between revisions of "Argon user guide/Wiring"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
(J4 power & motor port)
(J5 Inputs/Outputs)
Line 96: Line 96:
 
*Isolated digital outputs (4 pcs) - used for status indication
 
*Isolated digital outputs (4 pcs) - used for status indication
 
*Differential analog inputs (2 pcs) - used as [[Setpoint signal|Analog setpoint]]
 
*Differential analog inputs (2 pcs) - used as [[Setpoint signal|Analog setpoint]]
*Differential digital inputs (2 pcs) - used for pulse/direction or second encoder
+
*Differential digital inputs (2 pcs) - used for [[Pulse and direction|pulse and direction]], [[quadrature]] or [[PWM]] [[Setpoint signal|setpoint]] or secondary [[feedback devices|feedback device]]
 
*5V and GND output - used for supplying switches or external electronics
 
*5V and GND output - used for supplying switches or external electronics
  

Revision as of 19:02, 18 August 2013

This article state is work in progress & unchecked! Use at your own risk.

Wiring overview

Wiringoverview notitle.png

The minimum wiring for a servo system (after configuration state)
  1. Safety earthing to port J4 and preferably to the Argon case
  2. 24 VDC wiring to port J3
  3. Safe torque off and enable signals to port J2. See how.
  4. Motion controller wiring:
    1. if pulse & direction, analog, PWM or quadrature setpoint signal used, wire signals to port J5
    2. if setpoint delivered over SimpleMotion V2 bus, then a cable from SimpleMotion V2 compatible communication interface device to J2
  5. Axis limit switches wired to port J5
  6. Feedback device wiring to port J1
  7. Motor connection to port J4
  8. AC input power to port J4. Use an external fuse with this input.
Optional wiring
  1. AC Power line filter on the wire entering J4
  2. Wiring of optional braking resistor to port J4
  3. Motor solenoid brake wiring to port J3
Additionally following are required for drive configuration with Granity
  1. A cable from SimpleMotion V2 USB adapter to port J2

Ports and connectors

Argon front side connections

J1 feedback device port

J1 connector type is 15 pin female D-Sub and should be mated with 15 pin male D-Sub counterpart. See connector pinout. For connection examples, see article feedback device examples.

Pin-out

Many of the J1 pins have dual functions. The operating mode of pin is determined by feedback device mode selected from Granity.

Pin # Pin name Electrical function Alternate electrical function Uses
Shell PE Earth/case Feedback cable shield
1 HALL_W Hall sensor input, phase W Possible to use as general digital input in custom firmware Hall sensor input
2 HALL_V Hall sensor input, phase W
3 HALL_U Hall sensor input, phase W
4 CHE+ Differential input E+ Differential output E+ Serial encoder I/O
5 CHB- Differential input B- Analog input B+ Quadrature encoder/SinCos/serial encoder/resolver input
6 CHB+ Differential input B+ Analog input B-
7 CHA- Differential input A- Analog input A- Quadrature encoder/SinCos/serial encoder/resolver input
8 CHA+ Differential input A+ Analog input A+
9 5V_OUT Encoder supply 5V output Encoder supply
10 GND Encoder supply ground
11 CHE- Differential input E- Differential output E- Serial encoder I/O
12 CHD- Differential input D- Differential output D- Serial encoder I/O, resolver coil drive
13 CHD+ Differential input D+ Differential output D+
14 CHC- Differential input C- Encoder index channel/serial encoder input
15 CHC+ Differential input C+

J2.1 and J2.2 Simplemotion & E-stop ports

J2.1 and J2.2 are RJ45 type connectors and mates with standard Cat 5 & 6 ethernet cables. Both of these ports are connected pin-to-pin parallel to allow chaining of Argon devices. See also:

J3 24V power and motor brake port

J3 is a 3 pole terminal block type connector used for supplying 24VDC to drive and optionally controlling motor solenoid brake.

Pin # Pin name Description Connection
1 BK Motor brake output If motor has a 24V solenoid brake, connect brake between BK and V+
2 V+ 24V supply positive input Connect to 24V PSU +
3 V- 24V supply ground, on J1, J2.x and J5 connectors tied to GND Connect to 24V PSU -

24VDC typical current consumption is between 0.1 - 0.7ADC depending on how much current is drawn by feedback device and an optional motor brake.

Normally an ethernet type cable is plugged from J2.1 or J2.2 to SimpleMotion V2 USB adapter

J4 power & motor port

J4 is a 10 pole terminal block connector for several functions: earthing, AC power input, motor output, regenerative resistor output and HV DC link sharing. See the main article J4 connector wiring.

J5 Inputs/Outputs

J5 Is a 26 pin IDC connector located on the side of Argon. The connector serves as general purpose I/O including:

  • Isolated digital inputs (4 pcs) - used for limit & home switches and clear faults signal
  • Isolated digital outputs (4 pcs) - used for status indication
  • Differential analog inputs (2 pcs) - used as Analog setpoint
  • Differential digital inputs (2 pcs) - used for pulse and direction, quadrature or PWM setpoint or secondary feedback device
  • 5V and GND output - used for supplying switches or external electronics

See the main article Argon I/O connector electrical interfacing for pin-out and wiring guide.

J6 Expansion slot

This slot is reserved for Argon add-on card that may be installed inside the drive.

DIP Switches

DIP switches serves as address selector when connecting the drive to SimpleMotion V2 bus or Granity.

Mating parts

See list of Argon mating connectors and accessories

Wiring recommendations

Read general wiring recommendations articles at:

Basic wiring scheme

Basic wiring scheme of Argon (servo drive). Use of shielded cables is optional but highly recommended for EMI compliance and optimal reliability.

Argonwiringoverview.png

Notes:

  1. See SimpleMotion V2 port for wiring of E-stop and enable circuit
  2. See Argon user guide/Wiring/Feedback device examples
  3. See Argon user guide/J5 connector electrical interfacing
  4. See Setting device bus address
  5. See List of recommended power line & EMI filters