Difference between revisions of "Argon user guide/J4 connector wiring"
From Granite Devices Knowledge Wiki
[checked revision] | [checked revision] |
(→Pin-out) |
(→Pin-out) |
||
Line 7: | Line 7: | ||
! Pin #||Pin name !! Descrpition !! AC/BLDC motor connection || Brush DC motor connection | ! Pin #||Pin name !! Descrpition !! AC/BLDC motor connection || Brush DC motor connection | ||
|- | |- | ||
− | | 1||VN || HV DC link negative rail || colspan=2| Do not connect | + | | 1||VN || HV DC link negative rail || colspan=2| Do not connect, unless linking multiple drives with VN & VP to share their internal power supplies and braking resistor. |
|- | |- | ||
| 2||BR || Braking resistor output || colspan=2 rowspan=2|Optional braking resistor terminals. See [[Argon braking resistor]] | | 2||BR || Braking resistor output || colspan=2 rowspan=2|Optional braking resistor terminals. See [[Argon braking resistor]] |
Revision as of 22:18, 26 September 2013
J4 is a 10 pole terminal block connector for several functions: earthing, AC power input, motor output, regenerative resistor output and HV DC link sharing. See also the main article about Argon wiring.
Dangerous & non-isolated mains potential voltages are present in the connector J4! Keep away from this connector and its wiring when drive has been powered recently. Carefully read the page Power supply safe discharging before operating. |
Pin-out
Pin # | Pin name | Descrpition | AC/BLDC motor connection | Brush DC motor connection |
---|---|---|---|---|
1 | VN | HV DC link negative rail | Do not connect, unless linking multiple drives with VN & VP to share their internal power supplies and braking resistor. | |
2 | BR | Braking resistor output | Optional braking resistor terminals. See Argon braking resistor | |
3 | VP | HV DC link positive rail | ||
4 | PE ⏚ | Protective earth | Connect to motor PE conductor and motor cable shield | |
5 | U | Motor phase output | Motor U phase ¹ | Motor armature+ |
6 | V | Motor phase output | Motor V phase ¹ | Motor armature- |
7 | W | Motor phase output | Motor W phase ¹ | No connection |
8 | L | AC mains supply Line | Connect to AC supply line | |
9 | N | AC mains supply Neutral | Connect to AC supply neutral | |
10 | PE ⏚ | Protective earth | Connect to supply protective earth. This connection is always mandatory when any voltage larger than 30 VAC or 42 VDC is supplied to the device!. See Argon user guide/Earthing. |
¹ In some motors U,V,W phases are called R,S,T instead.
J4 wiring guide
Basic wiring scheme of Argon (servo drive). Use of shielded cables is optional but highly recommended for EMI compliance and optimal reliability. For recommended accessories, EMI filters etc, see Mating connectors and accessories.