Argon J4 connector wiring
Dangerous & non-isolated mains potential voltages are present in the connector J4! Keep away from this connector and its wiring when drive has been powered recently. Carefully read the page Power supply safe discharging before operating. |
Pin-out
Pin # | Pin name | Descrpition | AC/BLDC motor connection | Brush DC motor connection |
---|---|---|---|---|
1 | VN | HV DC link negative rail | Do not connect, unless linking multiple drives with VN & VP to share their internal power supplies and braking resistor. | |
2 | BR | Braking resistor output | Optional braking resistor terminals. See Argon braking resistor | |
3 | VP | HV DC link positive rail | ||
4 | PE ⏚ | Protective earth | Connect to motor PE conductor and motor cable shield | |
5 | U | Motor phase output | Motor U phase ¹ | Motor armature+ |
6 | V | Motor phase output | Motor V phase ¹ | Motor armature- |
7 | W | Motor phase output | Motor W phase ¹ | No connection |
8 | L | AC mains supply Line | Connect to AC supply line | |
9 | N | AC mains supply Neutral | Connect to AC supply neutral | |
10 | PE ⏚ | Protective earth | Connect to supply protective earth. This connection is always mandatory when any voltage larger than 30 VAC or 42 VDC is supplied to the device!. See Argon user guide/Earthing. |
¹ In some motors U,V,W phases are called R,S,T instead.
J4 wiring guide
Wiring multiple drives with power supply & braking resistor sharing
Note this drawing does not include wiring to motor (J4), motor brake (J3), feedback device (J1), controller (J5) and AC power input circuity.
Using HV DC bus sharing via VP and VN terminals or supplying external DC voltage to them, renders the safe torque off STO1 input unusable because STO1 is based on by cutting the AC supply. In order to preserve STO1 functionality with DC bus sharing, the STO1 signal must be fed simultaneously to all DC bus sharing drives. If an external DC supply is used (no AC input to L & N), then STO1 will not operate. STO1 will also be inoperable if DC voltage is supplied to L & N inputs instead of AC. With DC supply, STO1 ibput must be always powered as the internal relay may damage if STO1 used with DC supply. |
Detailed single drive wiring schematics
Basic wiring scheme of Argon (servo drive). Use of shielded cables is optional but highly recommended for EMI compliance and optimal reliability. For recommended accessories, EMI filters etc, see Mating connectors and accessories.
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.