Argon user guide/List of things needed
- The list of necessary things to build a working servo system with Argon
- Argon drive
- SimpleMotion V2 USB adapter
- 2 or more RJ45 Ethernet cables (see details & examples)
- Regulated 24 VDC power supply, output capability at least 0.5A per drive
- A Argon compatible servo motor
- Shielded power conductors for AC input, motor and braking resistor. Non-shielded will also work but increase EMI.
- Fuses with fuse holder
- Windows PC
- Motion controller. This may be also a software on a computer.
- Optional but highly recommended items
- Emergency stop button (normally closed NC type) or equivalent
- Braking resistor
- Ferrite core EMI filters, samples included with Argon package
- AC Power line filter, see list of recommended types here
- Needed for high current motors (>4A average)
- A cooling fan and/or additional heat sinks. See list of compatible heat sinks here.
- Tools needed
- Screwdrivers
- Wire cutter
- Skills needed
- Qualified electrician skills (license to make mains AC connections)
- Basic knowledge of servo systems
Read next |
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.