This page lists available mating connectors, accessories and spare parts for
Argon (servo drive). Most parts or equivalents are available from large number of distributors. Feel free to extend this list.
Description |
Manufacturer |
Part number |
Distributors and order codes
|
PLUG, D, SOLDER, 15WAY |
MULTICOMP |
5501-15PA-02-F1 |
|
Description |
Manufacturer |
Part number |
Distributors and order codes
|
D-SUB BACKSHELL, 15WAY |
MH CONNECTORS |
DPPK15-GREY-K |
|
Cable used for J2 should be shielded (S/FTP or FTP, not UTP) type.
Description |
Manufacturer |
Part number |
Distributors and order codes
|
Premium patch cable 0.5m |
VIDEK |
3962-0.5 |
Farnell 1525999
|
Premium patch cable 1m |
VIDEK |
3962-1 |
|
Premium patch cable 2m |
VIDEK |
3962-2 |
Farnell 1525753
|
Premium patch cable 5m |
VIDEK |
3962-5 |
Farnell 1525755
|
Premium patch cable 10m |
VIDEK |
3962-10 |
|
Shielded patch cable 0.5m |
VIDEK |
2992-0.5 |
Farnell 1517504
|
Shielded patch cable 1m |
VIDEK |
2992-1 |
|
Shielded Patch cable 2m |
VIDEK |
2992-2 |
Farnell 1517506
|
Shielded patch cable 5m |
VIDEK |
2992-5 |
Farnell 1517509
|
Shielded patch cable 10m |
VIDEK |
2992-10 |
|
Shielded patch cable 0.5m |
Assman |
A-MCSP-80005/B-R |
Digikey A-MCSP-80005/B-R
|
Shielded patch cable 1m |
Assman |
A-MCSP-80005/Y-R |
Digikey A-MCSP-80010/Y-R
|
Shielded patch cable 2m |
Assman |
A-MCSP-80020/Y-R |
Digikey A-MCSP-80020/Y-R
|
Shielded patch cable 3m |
Assman |
A-MCSP-80050/Y-R |
Digikey A-MCSP-80030/Y-R
|
Shielded patch cable 5m |
Assman |
A-MCSP-80050/Y-R |
Digikey A-MCSP-80050/Y-R
|
Shielded patch cable 10m |
Assman |
A-MCSP-80050/Y-R |
Digikey A-MCSP-80100/Y-R
|
Description |
Manufacturer |
Part number |
Distributors and order codes
|
RJ45 break-out board with DIN rail fixutre (convert RJ45 to screw terminals). Helpful for wiring STO and Enable wires. |
Camden boss |
CIM/RJ45 |
Farnell 2211819
|
This part is included with Argon package.
Description |
Manufacturer |
Part number |
Distributors and order codes
|
3 pole 0.2" pitch terminal
|
On Shore Technology Inc
|
OSTTJ035153
|
|
This part is included with Argon package.
Description |
Manufacturer |
Part number |
Distributors and order codes
|
10 pole 0.2" pitch terminal
|
On Shore Technology Inc
|
OSTTJ105153
|
|
Example of DIN rail attachable IDC terminal block/breakout board.
Mating connector type is 0.1" pitch 26 pin IDC ribbon cable socket, see example (pdf).
Description |
Manufacturer |
Part number |
Distributors and order codes
|
SOCKET, IDC, 2.54MM, 26WAY |
AMPHENOL |
T812126A100CEU |
|
SOCKET, IDC, WITH S/RELIEF, 26WAY |
MULTICOMP |
MC6FD026-30P1 |
|
Description |
Manufacturer |
Part number |
Distributors and order codes
|
IDC terminal block, 26WAY |
Camden boss |
CIM/202426W-IDCS |
|
Heat sinks & cooling & high power application[edit | edit source]
Description |
Manufacturer |
Part number |
Distributors and order codes
|
Half brick heatsink. Up to 4 pcs of standard half brick heat sinks can be fitted to a drive to improve cooling and increase maximum power output. Install with thermal grease. Note: M3 mounting screws must not reach through the 5 mm thick heat sink of the drive! |
Wakefield |
518-95AB |
|
Fuse, anti-surge, 6.3A. A replacement for original fuse in the drive. See replacing Argon fuse. |
SCHURTER |
0001.2512 |
Farnell 1360860
|
Fuse, anti-surge, 10A. A higher power alternative fuse. See replacing Argon fuse. |
SCHURTER |
0001.2514 |
Farnell 1360862
|
Fuse, anti-surge, 16A. A higher power alternative fuse. See replacing Argon fuse. |
SCHURTER |
0034.3129 |
Farnell 1360824
|
| Multiple drives may be connected behind one power line filter as long as total current consumption doesn't exceed filter rating |
| In most installations braking resistor is not needed at all. Resistor is needed in cases where fast moving motor with high inertial load is stopped rapidly causing conversion of the kinetic energy into electric current which needs to be dissipated by a resistor. Experimenting without resistor is safe as drive's overvoltage protection will prevent any damage occurring. If drive faults to overvoltage fault during deceleration, then try adjusting Over voltage fault thresholdFOV to higher value or add a braking resistor. |
Description |
Manufacturer |
Part number |
Distributors and order codes
|
82 ohm 250W braking resistor for 220-240VAC installation |
Tyco |
Tyco HSC 250 82R |
|
47 ohm 250W braking resistor for 110-120VAC installation |
Tyco |
Tyco HSC 250 47RJ |
Farnell 1619349
|
100 ohm 150W braking resistor for 220-240VAC installation |
TE Connectivity |
1630012-1 |
|
100 ohm 150W braking resistor for 220-240VAC installation |
Arcol |
HS150100RJ |
|
In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.
As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.
Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.