Difference between revisions of "Argon user guide/J4 connector wiring"

From Granite Devices Knowledge Wiki
Jump to: navigation, search
[checked revision][checked revision]
(Created page with "J4 is a 10 pole terminal block connector for several functions: earthing, AC power input, motor output, regenerative resistor output and HV DC link sharing. See also the main ...")
 
Line 1: Line 1:
J4 is a 10 pole terminal block connector for several functions: earthing, AC power input, motor output, regenerative resistor output and HV DC link sharing. See also the main article about [[Argon user guide/Wiring|Argon wiring]].
+
{{SetAUGTitle|J4 connector wiring}}{{ArgonManualNav}}J4 is a 10 pole terminal block connector for several functions: earthing, AC power input, motor output, regenerative resistor output and HV DC link sharing. See also the main article about [[Argon user guide/Wiring|Argon wiring]].
  
 
{{electricshock|Dangerous & non-isolated mains potential voltages are present in the connector J4! Keep away from this connector and its wiring when drive has been powered recently. Carefully read the page [[Power supply safe discharging]] before operating.}}
 
{{electricshock|Dangerous & non-isolated mains potential voltages are present in the connector J4! Keep away from this connector and its wiring when drive has been powered recently. Carefully read the page [[Power supply safe discharging]] before operating.}}

Revision as of 19:21, 18 August 2013

J4 is a 10 pole terminal block connector for several functions: earthing, AC power input, motor output, regenerative resistor output and HV DC link sharing. See also the main article about Argon wiring.


Pin-out

Pin # Pin name Descrpition AC/BLDC motor connection Brush DC motor connection
1 VN HV DC link negative rail Do not connect
2 BR Braking resistor output Optional braking resistor terminals. See Argon braking resistor
3 VP HV DC link positive rail
4 PE ⏚ Protective earth Connect to motor PE conductor and motor cable shield
5 U Motor phase output Motor U phase ¹ Motor armature+
6 V Motor phase output Motor V phase ¹ Motor armature-
7 W Motor phase output Motor W phase ¹ No connection
8 L AC mains supply Line Connect to AC supply line
9 N AC mains supply Neutral Connect to AC supply neutral
10 PE ⏚ Protective earth Connect to supply protective earth. This connection is always mandatory when any voltage larger than 30 VAC or 42 VDC is supplied to the device!

¹ In some motors U,V,W phases are called R,S,T instead.

J4 wiring guide

Basic wiring scheme of Argon (servo drive). Use of shielded cables is optional but highly recommended for EMI compliance and optimal reliability. For recommended accessories (EMI filters etc, see Mating connectors and accessories.

Argonwiringoverview.png