Argon parameterization

From Granite Devices Knowledge Wiki
< Argon user guide
Revision as of 20:42, 26 August 2013 by Tero K (Talk | contribs) (Motor)


Jump to: navigation, search

This article will describe how to set-up Argon parameters with Granity to make motor operational and ready for servo tuning.

Preparations and connection

As the goal is to parameterize and make motor operational, we should have:

  1. The drive and motor fully wired. However it's not required to have controller (to J5 port) or braking resistor connected at this point.
  2. Be familiar with the operation and parameters of Granity. Make sure you have read Granity user guide.
  3. Granity connection working. See Making the first Granity connection

Walk-through of initial parameterization

In this chapter we walk-trough all Granity tabs and modify the parameter needed. This guide assumes that the drive is in factory defaults state (not configured before). Restore drive to factory state can be done by uploading a firmware file to the drive.

Connect tab

No other actions than connect to drive needed on this tab. Once connection successful, proceed to the next tab.

Goals tab

The factory defaults (torque control as control mode and serial only as setpoint) as well as the other defaults are the correct ones for beginning.

Machine tab

In this tab we configure the motor and its feedback device.

Motor

Find motor parameters from the motor data sheet/manufacturer specifications.

  1. Choose motor type from the drowndown list [MT]
  2. Set motor pole count [MPC] (non-brush DC motors only). If unsure, see Determining motor pole count.
  3. Set maximum rated speed [MMS] of the motor, or alternatively the maximum allowed motor speed in the target application
  4. Set motor continuous [MMC] and peak [MMC] current values. If non-brush DC motor type has been selected, then these are measured as the peak value of sine.
  5. Set coil resistance [MR] and inductance [ML], these values are measured Phase-to-phase. If unavailable, perform Tuning torque controller manually after initial parameters are set.
  6. Set thermal time constant [MTC]. Motor thermal time constant value in seconds, used for thermal modeling of motor to avoid motor overheating with peak current [MMC]. If not available, use formula 200*motor_weight (kg) as approximate, so a 2 kg motor would get a 400 second time constant. There is no guarantee of accuracy of this method.

Feedback device

  1. Choose feedback device type from the dropdown [FBD]
  2. Set feedback device resolution. If FBD is quadrature encoder, then manufacturers typically give resolution as pulses per revolution (PPR) or lines per revolution (LPR) which are the same thing and shall be entered directly into [FBR] field. Some manufactures also call PPR as CPR.
  3. Configure the polarity of feedback device counting direction by [FBI] parameter. Motor and feedback device must have same electrical positive rotation direction to make a stable servo system. If your system shows no stability (instant following error after a motor "jump"), try changing this setting.
  4. Leave the Hall sensors Off [FBH] during initial setup. Enable later if necessary.

In no event the Product Information or parts hereof shall be regarded as guarantee of conditions or characteristics. The Product Information or any part thereof may also not be regarded as a warranty of any kind. No liability of any kind shall be assumed by Author with respect to Product Information or any use made by you thereof, nor shall Author indemnify you against or be liable for any third party claims with respect to such information or any use thereof.

As content of this Wiki may be edited by user community, Granite Devices Oy or it's affiliates do not take any responsibility of the contents of this Wiki. Use information at your own risk. However, Granite Devices staff attempts to review all changes made to this Wiki and keep information trustworthy.

Without written consent, Granite Devices' Products or Intellectual Property shall not be used in situations or installations where living beings, material property, or immaterial property could be harmed by the operation, features or failures of Product. Products may only be used in a way where hazards like moving parts, electric shock, laser radiation, or fire can't be realized even if the content of this Wiki would suggest otherwise.